6.6.1 Dismantling the sound enclosure
Note how the parts fit together.
➤ Undo the fixing screws and dismantle the sound enclosure.
6.6.2 Fitting the sound enclosure
Prior to any work requiring the opening of the pressure system, the machine must be fully iso‐
lated from the compressed air network and completely depressurised.
Precondition The sound enclosure is dismantled.
The power supply isolating device is switched off,
the device is locked off,
the absence of any voltage has been verified.
The machine is fully vented.
Verify the absence of pressure using a suitable measuring device (pressure gauge).
The machine has cooled down.
The user's shut-off valve between the machine and the compressed air network is closed.
Fig. 7 Fitting the sound enclosure
1
Enclosure base
2
Rear panel
3
Machine
4
Rubber pad
5
Front panel
6
Pressure line
7
Aperture
8
Cover panel
6
Installation