1. DANGER!
Electric voltage!
Risk of fatal injury caused by contact with live components!
➤ Switch off and lock out the power supply isolating device and check that no voltage is
present.
2. WARNING!
Compressed air!
Compressed air and devices under pressure can cause serious injury or cause death if the
contained energy is released suddenly.
➤ Fully vent all pressurised components and enclosures.
➤ Verify the absence of pressure using a suitable measuring device (pressure gauge).
3. Remove and disconnect the electric cable and pressure line from the machine.
4. Position the rear panel.
5. Attach the enclosure base to the rear panel.
6. Note the motor size and position the machine with the rear rubber pads in the prepared drilled
holes in the enclosure base.
7. Push the electric cable and pressure line through the apertures provided in the font panel and
connect them.
8. Screw the front and rear panels together.
The machine fan cowl must fit snugly against the sound enclosure foam.
9. Close the sound enclosure with the cover sheet.
6
Installation
6.6
Sound enclosure retrofit
34
Operator manual Reciprocating compressor
KCT blue T
No.: 902350 00E
Summary of Contents for KCT blue T Series
Page 2: ...Original instructions KKW PDENT 2 10 en SBA DENTAL T ANLAGE 20190503 092636...
Page 6: ...Contents iv Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 8: ...List of Illustrations vi Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 10: ...List of Tables viii Operator manual Reciprocating compressor KCT blue T No 902350 00E...