4.6 Options
The options available for your machine are described below.
4.6.1 Option H1
Machine mountings
These mountings allow the machine to be anchored firmly to the floor.
Fig. 9 Machine mountings
4.6.2 Option C16
LOAD-IDLE control by remote contact
The program module enables control of the LOAD phase by an external floating relay contact (remote
contact).
Do not remove the program module
■ The machine can no longer be operated once the module has been removed.
■ The program module can only control the machine in which it is first installed.
➤ Contact KAESER with any queries concerning the use of the program module.
Connections
Delivery condition
■ The connections in the controller are wire bridged.
■ With the bridge in place, the compressor controller toggles the machine between LOAD and
IDLE.
■ The switching point is the system pressure setpoint.
➤ Reset to the delivery condition if the machine is to be regulated by the internal controller
and the program module is still plugged in.
Remote contact function
■ Contact closed: LOAD
■ Contact open: IDLE
Program module
At the end of the idling period, the compressor switches to STANDSTILL and is in stand-by. The
length of the idling period depends on the control mode being selected.
If the «ON» key is pressed while the remote contact is open, the machine remains in stand-by and
starts as soon as the remote contact closes.
4
Design and Function
4.6
Options
Number: 9_6945 01USE
Service manual Screw compressor
Aircenter SX 3/7.5 SIGMA CONTROL BASIC
23