Battery charger
Value
Maximum charging current [A]
4
Protection class
IP 65
Tab. 46 Battery charger specification
2.9.4 Option ga
Generator
Generator specification
Characteristics
400V, 3-phase
230V, 3-phase
115V, 2-
phase
Rated power [kVA]
3-phase/2-phase
13.0
8.5
13.0
8.5
7.0
Rated power [kVA]
single-phase
7.0
5.0
7.5
5.0
5.0
Voltage constant [%]
balanced load
±5
Voltage constant [%]
single-phase, unbalanced
load
+6/−10
Rated power [kVA]
3-phase/2-phase
18.8
12.3
32.6
21.0
31.0
Rated current [A]
single-phase
30.0
21.7
32.6
21.0
45.0
Rated current [A]
Short-circuit
(0.3s / 170V)
300.0
260.0
330.0
330.0
420.0
Power factor (cos phi)
0.8 – 1
Frequency [Hz]
50
Speed [rpm]
3000
Distortion factor [%]
<5
Type
Synchronous internal pole (electronically controlled)
Enclosure protection
IP 54
Tab. 47 Generator specification
Reduced compressed air flow rate
Maximum working pres‐
sure [psi]
100
145
175
203
SIGMA airend
27–G
Flow rate [cfm]
81 – 296
63 – 240
56 – 215
93 – 194
* value depending on current supply
Tab. 48 Flow rate in generator mode
2
Technical Data
2.9
Options
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
19