Fig. 83 Battery labelling
1
Do not dispose of battery with municipal waste
2
Battery contains lead (if applicable)
1. Observe national disposal regulations!
2. Deliver batteries to the designated disposal system.
You actively contribute to the protection of the environment when you take used batteries to
the designated disposal system.
12.4.2 Draining operating fluids
Material Receptacle
Cleaning cloth
To prevent it from accidentally igniting, always drain the fuel when working on the interior of
the machine.
1. Drain and collect the following operating fluids from your machine.
Designation
Engine
Compressor
Fluid
Fuel
Cooling oil
Engine oil
Transmission oil
Coolant
Hydraulic oil
Reduction agent additive
from the exhaust gas after-treatment system
—
Tab. 109 Machine fluids
2. Drain and collect the following operating fluids from the options specified on your machine.
Designation
Low-temperature version option
Operating fluid
Antifreeze from the defroster
Tab. 110 Machine option fluids
Dispose of operating fluids and working materials and components contaminated with them in
accordance with applicable environmental protection regulations.
12.4.3 Draining condensate
Material Receptacle
Cleaning cloth
12 Decommissioning, Storage and Transport
12.4 Disposal
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
259