86
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Expansion Modules MAC00-B1/B2/B4
4.2.8
General description: “Multifunction I/O” when using a Bx module
The function of the Multifunction I/O is equal to that of the basic motor with the excep-
tion that the B1, B2 or B4 modules include an overvoltage protection and a dip-switch to
set up what kind of signal source feeds the input (if the Multifunction I/O is set up as in-
puts).
The illustration above shows how to set up the Multifunction I/O terminals as balanced/
push pull, NPN or PNP input. The illustrations below show examples of connections for
each of these signal types.
4.2.9
Connecting an NPN signal source to the Multifunction I/O
The drawing below shows how to connect an NPN source to the MAC00-B1, B2 or B4
multifunction I/Os. The diagram shows the A channel. The B channel must be connected
in the same manner. Ensure that the A- and B- terminals are unconnected in order to
maintain proper function.
Warning
: Voltages higher than 5V must under no circumstance be connected directly to
the input since this will damage the input permanently.
OFF
OFF
OFF
OFF
11
1
22
2
ON
ON
ON
33
3
44
4
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
TT0937GB
Dip-Switch setting
Input type setup for all common output types
The Dip switch is located at the rear side on all
3 module types MAC00-B1, B2 and B4.
NPN
NPN
NPN
PNP
PNP
PNP
NPN
NPN
NPN
PNP
Dipswitch 5+6 only at MAC00-B4. Please consult the B4 chapter.
Dipswitch 5+6 only at MAC00-B4. Please consult the B4 chapter.
Dipswitch 5+6 only at MAC00-B4. Please consult the B4 chapter.
PNP
PNP
INPUT
SETUP
INPUT
SETUP
INPUT
SETUP
A+
A+
A+
B+
B+
B+
Balanced or "push-pull" output connected
to the A and B input
NPN (sink) output connected to the A and B input
PNP (source) output connected to the A and B input
12
ON
34
ON
OFF
ON
OFF
NPN
PNP
NPN
PNP
INPUT
SETUP
A+
B+
NPN (sink) output connected to the A and B input
A+
A -
B+
B -
GND
Dip-Switch setting:
If used, the B+ terminal must be connected in the same manner as the A+ terminal.
NPN
Output
switch
TT0942GB
Signal source (PLC)
MAC motor with MAC00-B1, B2 and B4 expansion module
Ground
Warning:
Never connect voltages
higher than 5V directly to
the A or B terminals since
this can damage the inputs.
The and terminals must be left unconnected.
A-
B-
Dipswitch 5+6 only at MAC00-B4.
Please consult the B4 chapter.
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...