121
Expansion Modules MAC00-FC2/FC4
MAC00-FC2 with cables (optional):
If a number is added after the basic type number, for example MAC00-FC2-10, this suffix
indicates that the module is fitted with 10 m of cable in the I/O. The I/O cable covers all
the signal lines, i.e. RS232, Digital input 1-4, Limit inputs NL and PL and the Digital out-
puts 1-4
** : The light green wire (CV) can be difficult to distinguish from the green wire (TX) on some cables.
Digital Inputs
- Internal connector J2
Signal name
Pin no.
Description
Wire colour
IN1
1
Digital input 1
Red/black
IN2
2
Digital input 2
Green/black
IN3
3
Digital input 3
Violet
IN4
4
Digital input 4
Violet/white
NL
5
Negative limit input - If not used, do not connect.
Grey
PL
6
Positive limit input - If not used, do not connect.
Grey/black
IO-
7
I/O ground. This ground is shared with the output
ground
Pink/black
NC
8
(Reserved)
Black/white
CV
9
Secondary supply. Used during emergency stop
Light green **
CV
10
Secondary supply. Used during emergency stop
White
Digital Outputs
- Internal connector J4
Signal name
Pin no.
Description
Wire colour
O+
1
Supply for outputs - Must be connected to an ext.
supply.
Red/white
O1
2
Digital output 1 - PNP output
Green/white
O2
3
Digital output 2 - PNP output
Yellow/black
NC
4
(Reserved)
Blue/white
NC
5
(Reserved)
Orange/white
NC
6
(Reserved)
Brown/white
NC
7
(Reserved)
Pink
IO-
8
I/O ground. This ground is shared with the input
ground
Black
Interface
- including analogue input - Internal connector J1
Signal name
Pin no.
Description
Wire colour
TXPD
1
Transmit pull-down (Connect to TX if addr. not used).
Red
TX
2
RS232 Transmit (Connect to TXPD if addr. not used).
Green **
RX
3
RS232 Receive
Yellow
GND
4
Ground for RS232
Blue
AIN
5
Analogue input +/-10V or Zero sensor input
Orange
GND
6
Ground for AIN
Brown
Cable Screen
The cable-screen is internally connected to motor housing. Externally it must be connected to earth.
Unused wire
Orange/Black - is not used internally. It must be left unconnected.
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...