JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Expansion Module MAC00-FP2/FP4
“BUS2” - Profibus-DP Interface. M12 - 5-pin female connector
Signal name
Description
Pin no.
Cable: user
supplied
Isolation
group
5VDC
5V output. Can be used for ext. termination (Max 40mA)
1
-
2
A-
Terminal A (Siemens syntax) for the Profibus interface
2
-
2
DGND
Profibus-DP interface ground
3
-
2
B+
Terminal B (Siemens syntex) for the Profibus interface.
4
-
2
SHIELD
Cable shield. Internally connected to the motor housing.
5
-
2
“IO” - I/Os and RS232 interface. M12 - 8-pin female connector.
Signal name
Description
Function
Pin no.
JVL Cable
WI1000-M12
M8T05N
Isolation
group
IOC
I/O terminal C.
DIP 5 = OFF :
PL
input
DIP 5 = ON : O1
(PNP 25mA)
1
White
3
Tx
RS232 interface - transmit output
Important !: DIP1 must be turned ON. If addressing is
used it must be turned ON at minimum one
of the connected motors.
2
Brown
1
Rx
RS232 interface - receive input
3
Green
1
GND
RS232 Ground - also used with analogue input
4
Yellow
1
IOA
I/O terminal A.
DIP 2 = ON and DIP3 = OFF :
AIN
(Analogue input or S2 input)
DIP2 = OFF and DIP 3 = ON :
O2
(output 2 / PNP 25mA)
5
Grey
3 (1 when
used as
AIN)
IOB
I/O terminal B.
DIP 4 = OFF :
IN1 (input 1)
DIP 4 = ON :
O1 (PNP 25mA)
(output 1)
6
Pink
3
IO-
I/O ground to be used with IN1, NL, PL, O1, O2
7
Blue
3
IOD
I/O terminal D.
DIP 6 = OFF :
NL
(negative limit input)
DIP 6 = ON:
O+ (
output supply)
8
Red
3
Cable Screen
Some standard cables with M12 connector offer a screen around the cable. This screen on some cables is
fitted to the outer metal at the M12 connector. When fitted to the MAC00-FP4 module, this means that the
screen will have contact with the complete motor housing and thereby also the power ground (main ground).
Isolation groups
The MAC00-FP4 offers optical isolation at the digital inputs and outputs (IN1, NL, PL and O1-2). The table
shows a number for each pin. This number refers to the isolation group to which the pin is connected.
Isolation group 1 means that the terminal refers to the main ground (P-, GND and the motor housing).
Isolation group 2 means that the terminal refers to the Profibus-DP interface ground (DGND).
Isolation group 3 means that the terminal refers to the I/O ground (IO-)
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...