124
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Expansion Modules MAC00-FC2/FC4
Regarding the setting of SW3, see on next page.
“BUS2” - CANopen® interface. M12 - 5-pin female connector
Signal name
Description
Pin no.
Cable: user
supplied
Isolation
group
CAN_SHLD
Shield for the CAN interface - internally connected to the
motor housing
1
-
2
CAN_V+
Reserved for future purpose - do not connect
2
-
2
CAN_GND
CAN interface ground
3
-
2
CAN_H
CAN interface. Positive signal line
4
-
2
CAN_L
CAN interface. Negative signal line
5
-
2
“IO” - I/Os and RS232 interface. M12 - 8-pin female connector.
Signal name
Description
Function
Pin no.
JVL Cable
WI1000-M12
M8T05N
Isolation
group
IOC
I/O terminal C.
SW3 DIP 5 = OFF :
PL
input
SW3 DIP 5 = ON :
O1
output
1
White
3
Tx
RS232 interface - transmit output
Important !: DIP1 must be turned ON. If addressing is
used it must be turned ON at minimum one
of the connected motors.
2
Brown
1
Rx
RS232 interface - receive input
3
Green
1
GND
RS232 Ground - also used with analogue input
4
Yellow
1
IOA
I/O terminal A.
SW3 DIP 2 = ON and DIP3 = OFF
:
AIN
(Analogue input)
SW3 DIP2 = OFF and DIP 3 = ON
:
O2
(output 2)
(
AIN
is the analogue input. Re-
member to use the GND terminal
with AIN !).
5
Grey
3 (1 when
used as
AIN)
IOB
I/O terminal B.
SW3 DIP 4 = OFF :
IN1
(input 1)
SW3 DIP 4 = ON :
O1
(output 1)
6
Pink
3
IO-
I/O ground to be used with IN1, NL, PL, O1, O2
7
Blue
3
IOD
I/O terminal D.
SW3 DIP 6 = OFF :
NL
(negative limit input)
SW3 DIP 6 = ON :
O+
(
output supply)
8
Red
3
Cable Screen
Some standard cables with M12 connector offer a screen around the cable. This screen on some cables is
fitted to the outer metal at the M12 connector. When fitted to the MAC00-FC4 module, this means that the
screen will have contact with the complete motor housing and thereby also the power ground (main ground).
Isolation groups
The MAC00-FC4 offers optical isolation at the digital inputs and outputs (IN1, NL, PL and O1-2). The table
shows a number for each pin. This number refers to the isolation group to which each pin is connected.
Isolation group 1 means that the terminal refers to the main ground (P-, GND and the motor housing).
Isolation group 2 means that the terminal refers to the CAN interface ground (CAN_GND).
Isolation group 3 means that the terminal refers to the I/O ground (IO-)
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...