JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
39
2.6.16
Error message ’Internal Encoder error’ (only MAC400/800)
2.6.17
Error message ’Invalid Filter settings’ (only MAC400/800)
2.6.18
Error message ’Control voltage unstable’ (only MAC400/800)
Message no. / Message
16 / ’Internal Encoder error’
Type / Motor action
Unrecoverable error / Motor is set in passive mode.
Error condition
A malfunction in the internal encoder has been detected.
Possible cause of this error
- The encoder disc is broken because the motor have been ex-
posed to mechanical shock. Typical the shaft have been hit very
hard during mounting of the motor.
Solutions to avoid error
- Do not expose the shaft or the motor for mechanical shocks.
How to return to normal
operation
Return the motor for service.
Error bit / Firmware name
Bit 15 / ’INDEX_ERR’
Message no. / Message
17 / ’Invalid Filter settings’
Type / Motor action
Unrecoverable error / Motor is set in passive mode.
Error condition
The servo filter settings are not within valid ranges.
Possible cause of this error
- The setup file used has been corrupted.
- The setup file used is an old type not compatible with the ac-
tual motor version.
Solutions to avoid error
- Select a new filter or contact your JVL.
How to return to normal
operation
- Correct the servo filter setting.
Servo filter adjustment, page 43
- Cycle the 24VDC power.
Error bit / Firmware name
Bit 16 / ’OLD_FILTER’
Message no. / Message
18 / ’Control voltage unstable’
Type / Motor action
Unrecoverable error / Motor is set in passive mode.
Error condition
The control voltage (24VDC at the P+ and P- terminals) has been
unstable and detected outside the specified voltage range for a
too long time.
Possible cause of this error
- The control voltage has been detected outside the nominal
voltage range.
- The voltage has been applied too slowly with variations.
Solutions to avoid error
- Make sure that the voltage is stable in the specified voltage in-
terval.
- Make sure that the voltage is applied in less than 500mS.
How to return to normal
operation
- Cycle the 24VDC power. A reset will not clear the error.
Error bit / Firmware name
Bit 17 / ’U24V ’
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...