80
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Expansion Modules MAC00-B1/B2/B4
4.2.2
General hardware aspects
All internal and external main connections can be seen in the illustration below.
Please note that a few features are only available in MAC00-B4 and partly in B2.
4.2.3
General hardware description
The MAC00-B1, B2 and B4 modules offer the following external connections.
•
Power supply (P+/P-)
These terminals are used for the main supply of the motor. A voltage b12
and 48VDC (MAC50-141) and +12-32VDC (MAC400-800) must be connected.
• Analogue input (AIN)
The analogue input is used either as an analogue input or digital input. When used as
an analogue input, it can control velocity, torque or position depending on which
mode is set for motor operation. When used for digital input, it can be used in posi-
tion-related modes for the external zero-search sensor. Also in “Air Cylinder Mode”
the analogue input is used as a trigger input.
For a functional description, please refer to
General Analogue input (AIN) description
(continued)
P+
AIN
P+
AIN
P-
GND
P-
GND
O+
OCM
O1
O2
A+
A
O1
RX
B+
O2
TX
B
GND
Rx
GND
Tx-PD
Tx
Overvoltage
protection
Control
Supply
PNP Output
Driver
Asynchronous
serial interface
Interface
Control
Power supply
MAC50-141: +12-48V
MAC800: +12-32V
Analogue input
or Zero search input
±10V nom. or up to 32V
Multifunction I/O
Status outputs
RS485 Interface
RS232 Interface
Basic MAC motor with MAC00-B1, B2 or B4 module inserted.
TT1052GB
MAC00-B1/B2/B4 expansion module
Basic MAC motor
(MAC050 to 800)
Power supply
Analogue input
Multifunction I/O
(Bidirectional)
Status outputs
Asynchronous
interface
Power ground (P-) is not connected in the MAC00-Bx module
Fuse F10A
This GND is only available at the MAC00-B1
At the MAC00-B2 and B4 the P- or OCM is
used as ground for AIN
Control supply only in MAC00-B2 and B4.
This feature makes it possible to keep
communication and position data active
while main power P+ is removed.
A
TERM
B
2 channel
differential
Transceiver
These terminals are
not available at the
external connector at
MAC00-B4. Use the
internal switch to
enable the feature
B -
A -
B+
A+
Summary of Contents for MAC050
Page 2: ......
Page 4: ......
Page 6: ...2 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 7: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 3 1 Introduction ...
Page 20: ...16 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 80: ...76 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 112: ...108 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 254: ...250 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 255: ...JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 251 5 Appendix ...
Page 300: ...296 JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 ...
Page 306: ...6 Index JVL Industri Elektronik A S User Manual Integrated Servo Motors MAC050 800 302 ...