Control, Power and IO Terminals
Label
Type
Description
IN1
2 Way
Energiser control input (dry contact). Defaults to normally open.
Can be used for a remote switch or a radio receiver. The receiver may be powered
from the 12V terminal.
Gate
2 Way
Energiser control input, defaults to normally open low power but may also be
assigned to gate input. When the unit is armed and the gate is opened, it will trigger
the gate alarm.
Keypad
3 Way
Supplies power and data line for an external keypad. The +12V source on these
terminals is protected with 1A self resetting fuse.
Siren
2 Way
Switched 12 volt output. Low side switched. 35W max (including strobe). A buffer
relay should be used when connecting these outputs to an alarm panel.
Strobe
2 Way
Switched 12 volt output. Low side switched. 35W max (including siren). A buffer
relay should be used when connecting these outputs to an alarm panel.
AC IN
3 Way
16Vac power input. Fused via F3 3A self resetting fuse. Note: 24Vdc may also be
used, in which case the polarity should be + to the left pin.
The Earth terminal (far right) may be required to be connected to mains earth in
some countries, consult your local wiring guidelines.
Relay 3
3 Way
May be set to any of 16 alarm conditions. Defaults to zone 1 alarm.
Relay 4
3 Way
May be set to any of 16 alarm conditions. Defaults to zone 2 alarm.
Relay 5
3 Way
May be set to any of 16 alarm conditions. Defaults to zone 3 alarm.
Relay 6
3 Way
May be set to any of 16 alarm conditions. Defaults to zone 4 alarm.
J5
Jumper Short these two contacts to p12v power to the common contact of Relay 3.*
J6
Jumper Short these two contacts to p12v power to the common contact of Relay 4.*
J7
Jumper Short these two contacts to p12v power to the common contact of Relay 5.*
J8
Jumper Short these two contacts to p12v power to the common contact of Relay 6.*
*+12v power limited to a maximum of 30W combined for relays 3-6, including Siren and Strobe outputs.