An alarm will also sound if Con
trol Input 2 is assigned to the “gate” function and the gate input is opened for longer
than the Gate delay time.
After the siren has cycled on and off according to the times and numbers set in options, the siren will stop
sounding. The on and off timing can be set in the programmable options. The Strobe will remain on. After a further
delay (Auto Rearm Time) the siren will again respond to the next alarm condition with a new set of on / off cycles.
If the alarm condition is removed, the siren will stop a
fter the end of the current “on” time (Siren On Time).
If the siren is silenced (by
entering PIN#) then the siren will enter the next “off” cycle (Siren Off Time). If the alarm
condition is still present (voltage is low) the siren will sound again after th
e preset “off” time. If the alarm condition is
not present the Energiser is instantly rearmed, irrespective of the auto-rearm setting.
To Silence the Alarm
If there is no Keypad attached simply disarm the ZLM4 using the Key switch or magnetic fob.
Using a Keypad, enter your User PIN and press #. This will silence the alarm but not disarm the system; the armed
light will still be on. The system will be ready for the next alarm.
Note: This silence function will not operate if the ZLM4 is part of a Z series
“group”.
The last alarmed Zone will still be displayed on the front panel LCD and the Keypad.
The siren and strobe are ready to respond again if triggered.
To Disarm
If there is no Keypad attached simply disarm the ZLM4 using the Key switch or magnetic fob.
Using a Keypad, disarm the system by entering your User PIN and press #.
The Fence or Gate light on the ZLM4 will remain on to show the Alarm memory. This can be cleared by entering
the Clear Alarm memory command *1#. The Alarm memory will also be cleared when the ZLM4 next Arms.
To Clear Alarm Memory
After an alarm occurs, pressing *1#, will clear the alarm memory. If the problem still exists the unit will alarm again.
Changing your User PIN
Enter the current 4 digit PIN and press *0#. This enters User Programming mode.
Enter your new PIN (must be 4 digits) and then #.
Press *# to exit User Programming mode.
Make sure your new PIN works by using it to arm the energiser.
The default User PIN is 1234.
For example, the following Keypad sequence will change the User PIN to 8015 from the default PIN:
1 2 3 4 * 0 # 8 0 1 5 # * #
Standby Battery
Should there be a loss of mains power, the Power light on the keypad will go off. The status LED on the ZLM4 front
panel will flash twice and the Keypad will show Trouble
– AC Fail.
If the loss of power is prolonged, the battery may become discharged and become ineffective. The Power light on
the keypad will start to flash indicating that the battery charge is low. The status LED on the ZLM4 front panel will
flash three times and the Keypad will show
TROUBLE: LOW BAT
If the standby battery requires replacement, the Status LED on the Energiser will flash 3 times even after the mains
power has been restored.
Internal Beeper/Keypad Beeper
Depending on the Chime Mode setting, the internal beeper and keypad beeper will sound when there is a fence
alarm, a gate alarm, a general alarm or a door chime. On flat battery the keypad will always beep 4 times before
the energiser automatically enters low power mode to preserve the battery. On AC Fail it will not beep.
Note: The Internal beeper also beeps at Power up.