Programming Options in Detail
Zone 1 Fence Voltage Alarm Level (01xx#)
Sets the voltage below which the zone alarm will occur. If the fence voltage
measured at
the return “R” loop terminal falls below this level for more than the
Missed pulse count a fence alarm (zone 1) will occur. The value is set directly,
not via a table.
For example to set a threshold of 25V enter: 0 1 2 5 #
Setting this option to 0 effectively turns off fence voltage monitoring.
Warning: Setting this level to higher than the normal running voltage of the fence
will result in continuous fence alarms.
Zone 2 Fence Voltage Alarm Level (02xx#)
As above for zone 1.
Zone 3 Fence Voltage Alarm Level (03xx#)
As above for zone 1.
Zone 4 Fence Voltage Alarm Level (04xx#)
As above for zone 1.
Missed Pulse Count (06xx#)
This option enables the pulse count to be varied from the default (3). This is the
number of bad or missing pulses that are counted before the alarm occurs. Note:
The lower this option is set the more likely you are to get false alarms.
The value is set directly. For example to set a threshold of 2 bad or missing
pulses enter: 0 6 0 2 #.
Battery Alarm Voltage (07x#)
This option sets the battery voltage threshold below which the general
alarm will activate. The default Battery Alarm Voltage is 10.0 Volts. This
alarm can be set to activate one of the relays, and is part of the General
alarm.
Value (x)
Alarm Level
Minimum
0
0.0 V
Default
20
20V
Maximum
40
40 V
Value (x)
Missed Pulses
0
1
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Value
Alarm
0
9.0 V
1
9.5 V
2
10.0 V
3
10.5 V
4
11.0 V
5
11.5 V
6
12.0 V
7
12.5 V
8
13.0 V
9
13.5 V