© JVA Technologies Pty Ltd
Page 30 of 32
Issue:3/03/2021 9:39:00 AM
OEM technical manual.docx
Group Mode (26x#)
A group must have only 1 master. The other Energisers/Monitors in the
group are slaves.
The correct procedure is:
Connect the keypad to each Energiser/ZLM4 in turn, programming each Option
as required before linking the Keypad bus into a group.
The ZLM4 should only be a group master if there are no Z energisers in the
group. I.e. the group is made up of one or more
ZLM4’s only.
If a PAE212 TCP/IP adaptor is used, it is the group master. All other devices
should be set to slaves.
All energisers must be synchronised, therefore non-synchronised agricultural
energiser must never be used in a system with a ZLM4. This allows the ZLM4
pulses to be synchronised with other ZML4s or Z-Series Energiser.
Value (x)
Mode
0
No Group
1
Master
2
Slave 1
3
Slave 2
4
Slave 3
5
Slave 4
6
Slave 5
7
Slave 6
8
Slave 7
9
Slave 8
10
Slave 9
11
Slave 10
12
Slave 11
13
Slave 12
14
Slave 13
15
Slave 14