Programmable Options Table
Option
Function
Default
Description
01
Voltage alarm
level zone 1
20V
Sets the voltage below which the fence alarm will occur. If the
return voltage falls below this level for more than the Missed
pulse count a fence alarm (zone 1) will occur. Setting to 0
disables the alarm.
02
Voltage alarm
level zone 2
20V
As above
03
Voltage alarm
level zone 3
20V
As above
04
Voltage alarm
level zone 4
20V
As above
05
HV sensitivity
0
0-1. Setting 0 turns HV alarms off (added 1v25).
06
Missed Pulse
Count
3
Sets the number of pulses which may be missed before the
alarm is activated
07
Battery Alarm
Voltage
2 (10V)
Sets the battery voltage threshold below which the general
alarm will activate
08
Siren On Time
4 (3 Mins)
Sets the time that the siren (and keypad beeper) will stay on
after an alarm
09
Siren Off Time
4 (10 Min)
The amount of time the siren will be off for after the
on
time
has expired
10
Siren Cycles
3
The number of times the siren will sound for the time set in
on
time
above. After this many cycles the siren will automatically
mute
11
Input type
0 (N/O)
Allows the control inputs to be changed from normally open to
normally closed.
12
Input 2 Function
0
Gate switch
13
Gate Delay
2 (1 Min)
Gate switch open time till alarm
14
Chime Mode
2 (siren)
Allows the keypad and internal beeper function to be altered
15
Not Used
0
16
Binary Options
8
Miscellaneous options
17
Not Used
0
18
Not Used
4
19
Not used
0
20
Auto Rearm
Time
0
Sets the time which must elapse after an alarm has timed out
(completed the siren cycles) before the unit will automatically
re-arm ready for the next alarm event.
21
Relay 1
8
Used to assign an alarm function to relay 1 (siren output)
22
Relay 2
9
Used to assign an alarm function to relay 2 (strobe output)
23
Relay 3
Used to assign an alarm function to relay 3 (Zone 1 alarm)
24
Relay 4
Used to assign an alarm function to relay 4 (Zone 2 alarm)
25
Relay 5
Used to assign an alarm function to relay 5 (Zone 3 alarm)
26
Group ID
0
If used as part of a group, this sets the device ID
27
Relay 6
Used to assign an alarm function to relay 6 (Zone 4 alarm)