Table 16: EIA-530 DCE Connector Interface Signals for HD-26 to Female DB-25 (continued)
Circuit
Description
DB-25
Pin
HD-26
Pin
CD
Data terminal ready (DTR)—A (input to CTP)
20
12
LL
Local loopback (LL) (input to CTP)
18
13
BB
Receive Data (RD)—B (output from CTP)
16
14
DD
Receive Clock—B (output from CTP)
9
15
DB
Transmit Clock (from DCE)—B (output from CTP)
12
16
DA
Transmit Clock (from DTE)—B (input to CTP)
11
17
BA
Transmit Data—B (input to CTP)
14
18
CF
Data carrier detect (DCD)—B (output from CTP)
10
19
CC
Data set ready (DSR)—B (output from CTP)
22
20
RL
Remote loopback (RL) (input to CTP)
21
21
TM
Test mode (TM) (output from CTP)
25
22
Ground
Signal ground (GND)
7
24, 26
CD
Data terminal ready (DTR)—B (input to CTP)
23
25
EIA-530 Connector Interface Signal Pinouts (DB-25 Male DTE)
lists the EIA-530 interface signal pinouts for the HD-26 connector to the male DB-25
connector for the CTP151 platform.
Table 17: EIA-530 DTE Connector Interface Signals for HD-26 to Male DB-25
Description
DB-25 Pin
HD-26 Pin
Transmit Data—A (output from CTP)
2
1
Transmit Clock (from DTE)—A (output from CTP)
24
2
Transmit Clock (from DCE)—A (input to CTP)
15
3
35
Summary of Contents for CTP151 Platform
Page 1: ...Juniper Networks CTP151 Circuit to Packet Platform Hardware Guide Published 2020 02 07...
Page 12: ...1 PART Overview CTP151 Platform Overview 3 CTP151 Interface Modules 9...
Page 13: ......
Page 26: ......
Page 50: ......
Page 58: ......
Page 71: ...CTP151 Platform Overview 3 63...
Page 78: ......
Page 88: ......
Page 100: ...7 PART Troubleshooting Troubleshooting Hardware and Power Failures 97...
Page 101: ......