5.1
Truck does not start
Possible Cause
Remedy
Battery connector not inserted
Check the battery connector
and insert if necessary
Emergency Disconnect switch pressed
Release the Emergency Disconnect
switch, see page 64
Key switch set to O
Set the key switch to “I”
Deadman switch not pressed
Press deadman switch
Battery charge too low
Check battery charge,
Charge battery if necessary, see
page 38
Faulty fuse
Incorrect ISM access module
transponder used
Use correct transponder
Incorrect CANCode PIN entered
Enter correct PIN, see page 86
5.2
Load cannot be lifted
Possible Cause
Remedy
Truck not operational
Carry out all measures listed under
“Truck does not start”.
Hydraulic oil level too low
Checking the hydraulic oil level
Battery discharge monitor has switched
off
Charge the battery
Faulty fuse
Check fuses
Excessive load
Note maximum capacity, see data plate.
Switch in mast implausible (E-2124)
Emergency recovery (travel at max. 1.5
km/h and lowering possible when truck is
in rider mode). Contact the
manufacturer's service department.