Charging the battery
Requirements
– Electrolyte temperature b15°C and +35°C
Procedure
• Open or take off the tray lid or covers from the battery compartment.
• Connect the battery to the switched off charger, ensuring the terminals are
connect (positive to positive and negative to negative).
• Switch on the charger.
Z
The electrolyte temperature rises by approx. 10°C during charging. If the
temperatures are permanently higher than 40°C or lower than 15°C, a
temperature-dependent constant voltage control of the charger is required. The
adjustment factor must be applied with -0.004 V/C per °C.
The battery is charged.
Z
Charging is considered to be complete when the electrolyte density and battery
voltage remain constant for more than 2 hours.
Compensation charging
Compensation charging is used to ensure the useful life and maintain capacity after
full discharge and repeated insufficient charging.
Z
Compensation charging should be carried out weekly.
Trickle charging
Battery trickle charging is partial charging that extends the daily application time.
Higher average temperatures occur during trickle charging which can reduce the
useful life of the batteries.
Z
Trickle charges should only be performed when the charge level is below 50%. Use
replacement batteries instead of regular trickle charging.
Z
Avoid trickle charging with PzV batteries.
161
04.19 en-GB
Summary of Contents for ESE 220
Page 1: ...ESE 220 320 03 10 Operating instructions 51163703 04 19 en GB ESE 220 ESE 320...
Page 2: ...2...
Page 4: ...4 04 19 en GB...
Page 10: ...10 04 19 en GB...
Page 14: ...14 04 19 en GB...
Page 49: ...2 Displays and Controls 5 7 10 49 50 51 52 53 11 14 13 54 55 56 17 49 04 19 en GB...
Page 70: ...17 10 70 04 19 en GB...
Page 79: ...The brake is now released The truck can be moved 79 04 19 en GB...
Page 148: ...148 04 19 en GB...