PzV and PzV-BS lead-acid batteries with sealed armour
plated cells
5.1
Description
PzV batteries are sealed batteries with fixed electrolytes, to which no water can be
added over the entire lifespan of the battery. Relief valves are used as plugs which
are destroyed when opened. During operation the same safety requirements apply to
the sealed batteries as for batteries with liquid electrolyte. This is to avoid electric
shock, explosion of the electrolyte charging gases or hazardous electrolyte burns if
the cell vessels are destroyed.
Z
PzV batteries are low gassing, but not gassing-free.
Electrolyte
The electrolyte is sulphuric acid which is fixed in gel. The density of the electrolyte
cannot be measured.
5.1.1 Battery nominal data
1.
Product
Traction battery
2.
Nominal voltage
2.0 V x no. of cells
3.
Rated capacity C5
See data plate
4.
Discharge current
C5/5h
5.
Rated temperature
30 °C
Limit temperature
1
1. Higher temperatures shorten the useful life, lower temperatures reduce
the available capacity.
45°C, not permissible as operating
temperature.
6.
Rated density of the electrolyte
Cannot be measured
7.
System rated electrolyte level
Cannot be measured
Summary of Contents for ESC 316
Page 1: ...06 13 11 14 51314819 ESC 316 316z Operating instructions G ESC 316z ESC 316 ...
Page 3: ...11 14 EN 2 ...
Page 9: ...11 14 EN 8 ...
Page 13: ...11 14 EN 12 ...
Page 22: ...21 11 14 EN b11 b5 b2 x Wa e a 2 Ast a 2 h13 h2 h3 h1 h4 l2 y l1 l c m2 s 187 1278 h6 Q ...
Page 46: ...45 11 14 EN 2 Displays and Controls 7 12 53 54 55 6 56 13 16 15 57 58 59 20 ...
Page 103: ...11 14 EN 102 ...
Page 157: ......