137
11
.1
4
E
N
4
Lead acid batteries with armour plated cells and liquid
electrolyte
4.1
Description
Jungheinrich traction batteries are lead acid batteries with armour plated cells and
liquid electrolyte. The names of the traction batteries are PzS, PzB, PzS Lib and PzM.
Electrolyte
The rated density of the electrolyte assumes a temperature of 30°C and the rated
electrolyte level is fully charged. Higher temperatures will reduce, lower temperatures
will increase the electrolyte density. The adjustment factor is ± 0.0007 kg/l per K, e.g.
electrolyte density 1.28 kg/l at 45°C corresponds to a density of 1.29 kg/l at 30°C.
The electrolyte must conform to DIN 43530 Part 2 purity regulations.
4.1.1 Battery nominal data
1.
Product
Traction battery
2.
Nominal voltage
2.0 V x no. of cells
3.
Rated capacity C5
See data plate
4.
Discharge current
C5/5h
5.
Nominal electrolyte density
1
1. Reached within the first 10 cycles.
1.29 kg/l
6.
Nominal temperature
2
2. Higher temperatures shorten the useful life, lower temperatures reduce
the available capacity.
30 °C
7.
System rated electrolyte level
up to "Max" electrolyte level marking
Limit temperature
3
3. Not permissible as operating temperature.
55°C
Summary of Contents for ESC 316
Page 1: ...06 13 11 14 51314819 ESC 316 316z Operating instructions G ESC 316z ESC 316 ...
Page 3: ...11 14 EN 2 ...
Page 9: ...11 14 EN 8 ...
Page 13: ...11 14 EN 12 ...
Page 22: ...21 11 14 EN b11 b5 b2 x Wa e a 2 Ast a 2 h13 h2 h3 h1 h4 l2 y l1 l c m2 s 187 1278 h6 Q ...
Page 46: ...45 11 14 EN 2 Displays and Controls 7 12 53 54 55 6 56 13 16 15 57 58 59 20 ...
Page 103: ...11 14 EN 102 ...
Page 157: ......