8 Programming
65
Display
Edit
Selection/input
with keys
Enter
Continue with
3
(RES.THERM.)
1 CHARACT: Pt100
Pt 100
(–200 to +850°C)
Pt 100
(–200 to +649°C, JIS)
Pt 500
(–200 to +850°C)
Pt 1000
(–200 to +850°C)
Ni 100
(–60 to +180°C)
X1
customized 1
X2
customized 2
h
,
R
E
customized
X1 or X2:
10 (FILTER)
otherwise:
31
31
1 CONNECTION: 2/3-wire
2/3-wire
4-wire
Define type of
connection of resistance
thermometer:
(2/3-wire or 4-wire)
h
,
R
E
32
32
1 UNIT: °C
°C, °F
h
,
R
E
33
33
1 RANGE BEG: –200.0 °C
Input start of
measurement range
h
,
R
,
l
,
r
,
S
E
Check
range start
according to
characteristic
34
34
1 RANGE END:+850.0 °C
Input end of
measurement range
h
,
R
,
l
,
r
,
S
E
Check
range end
according to
characteristic
end – start
≥
15°C
10 (FILTER)
4
see table below!
10
1 FILTER: +0.800 sec
Input filter constant
(value range: 0.0 — 10.0)
h
,
R
,
l
,
r
,
S
E
Check
value range
0.0 — 10.0
h
forwards
R
backwards