8 Programming
58
8.3.3 Summer time
Input of a time interval during which the
system clock of the recorder is changed to
summer time.
Example:
Summer time start: 31.03.96, 2:00 hrs
Summer time end: 27.10.96, 3:00 hrs
On 31.03.96 at 2:00 hrs the system clock is
advanced automatically one hour to 3:00 hrs.
On 27.10.96 at 3:00 hrs the system clock is
automatically put back one hour to 2:00 hrs.
The time interval for summer time
always applies only to the period in-
dicated.
It has to be re-programmed afresh
for each year.
Display
Edit
selection/input
with keys
Enter
Continue with
SUMMERTIME
E
SUMMERTIME: OFF, ON
Input status
h
,
R
E
ON:
2
OFF:
h
forwards
R
backwards
2
(ON)
BEGIN: 31.03.96 00:00
Input date:
DD:MM:YY
h
,
R
l
,
r
E
Check date
3
3
BEGIN: 31.03.96 02:00
Input time:
hh:mm
h
,
R
l
,
r
E
Check time
4
4
END: 27.10.96 00:00
Input date:
DD:MM:YY
h
,
R
l
,
r
E
Check date
5
5
END: 27.10.96 03:00
Input time:
hh:mm
h
,
R
l
,
r
E
Check time
h
forwards
R
backwards
Summary of Contents for LOGOLINE 500d