10 Extra Codes and accessories
112
10.3 External relay module ER8
The external relay module ER8 adds eight
switching outputs to the recorder. The re-
lays are freely assigned to the recorder
channels in the setup program
(
Section 10.4).
The limit for each relay is programmed at
the parameter level.
The switching differential about the limit set-
ting can be freely configured in the setup
program. The limit comparator functions
lk7 and lk8 are available
Section 8.3.5
Section 8.6.1
The external relay module ER8 can
only be operated when the Extra
Code 259 is installed.
When the setup connector is
plugged into the recorder all relays
are de-energised.