12 Appendix
Power consumption
35 VA max.
Data back-up
by lithium battery in RAM, more than 4 years;
by storage capacitor 2 days at 15 — 25 °C
ambient temperature.
Additional back-up in EEPROM.
Electrical connection
at the back through screw-clamp connec-
tors, max. conductor cross-section 2.5 mm
2
or 2 x 1.5mm
2
with core sleeves.
Setup connector behind the swing-up LED
dot-matrix display.
Permitted ambient
temperature range
–10 to +50 °C
Ambient temperature drift
0.3 % per 10°C
Permitted storage
temperature range
–20 to +70°C
Climatic conditions
rel. humidity 75 % max., no condensation
Operating position
NL 90 ± 30 to DIN 16 257 (vertical)
Protection
to EN 60 529 Category 2
- front IP54
- front IP65 (with extra code 266,
without extra code 265)
- rear IP20
Electromagnetic compatibility (EMC)
EN 61 326
Interference emission:
Class B
Immunity to interference:
industrial requirements
Electrical safety
to EN 61 010
Approvals/marks of conformity
Mark of conformity:
c UL us
Testing laboratory:
Underwriters Laboratories
Certificates/certification numbers:
E 201387
Test basis:
UL 3111-1
CAN/CSA-C22.2 No. 1010.1-92
valid for:
the flush-mounted instrument;
not in conjunction with any housing extra
code
Summary of Contents for LOGOLINE 500d
Page 106: ...9 Consumables 106 9 2 Removing and replacing the chart cassette S F ENTER E S F ENTER E...
Page 108: ...9 Consumables 108 9 2 1 Changing the roll chart 1 5 2 6 3 7 4 8...
Page 109: ...9 Consumables 109 9 2 2 Changing the fanfold chart 1 4 2 5 3...
Page 110: ...110 10 Extra Codes and accessories 10 1 Converting the chart cassette 1 3 2 4...
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......