6 Project planning
44
Status:
Data for connecting the JUMO IO device to the IO
controller
In addition to the essential IP configuration data for the
JUMO IO device, additional important information is dis-
played, e. g. the "App Version" from the module configura-
tion of the device (see chapter 6.2 "Configuring PROFINET
modules", page 36) and in the "Status" field the connection
status of the JUMO IO device. The last PROFINET diagno-
sis event is displayed as the current connection status:
•
Unknown
Connection status unknown (no previous diagnosis
event)
•
Link Up/Down
At least one RJ45 switchport of the PROFINET optional
board has established or lost a physical connection.
•
Network Up/Down
IP configuration status of the IO devices valid or invalid
(e. g. address conflict).
•
PLC Connection Up/Down
The IO device has established or lost a communication
connection to the IO controller.
Info:
Network data of the IO device
The network configuration data of the PROFINET interface
such as the MAC addresses of the 3 interfaces of the PROF-
INET optional board are displayed here (cf.
chapter 6.3.2 "Communication parameters", page 40).
The individual MAC addresses:
•
MAC address
MAC address of the internal interface (SMK socket) of
the PROFINET optional board for connection to the in-
ternal Ethernet interface of the JUMO IO device (COM2
slot); this MAC address represents the JUMO IO device
in your project planning for device detection and topolo-
gy recognition
•
MAC port 1/2
MAC addresses of the two switchports (RJ 45) of the
PROFINET optional board
Version:
Version numbers of hardware and software com-
ponents
Summary of Contents for AQUIS touch P
Page 2: ......
Page 4: ...Contents...
Page 6: ...1 Safety information 6...
Page 8: ...2 Compatibility and system requirements 8...
Page 10: ...3 Electrical connection 10...
Page 46: ...6 Project planning 46...
Page 48: ...7 Error messages 48...
Page 49: ...49 8 Annex 8 Annex 8 1 PROFINET certificate...
Page 50: ...8 Annex 50...
Page 51: ......