– 40 –
Classifi
-
cation of
parameters
No.
Parameter name
Range
Standard
value
Meaning of parameter and comment
Reset
setting
P36
Clamp at the time of reset
-
ting
Yes/No
No
Cassette clamp comes down when
returning to origin
P264
Clamp is opened after
manual resetting
Yes/No
Yes
Cassette clamp goes up when returning
to origin by pressing the reset button
P38
Return-to-origin method
XY simul-
taneous / X
preference / Y
preference
XY simul-
taneous
"XY simultaneous" means that both the
X and Y axes simultaneously start the
"return to origin" operation. "X priority"
means that the X axis returns to its
origin first, then the Y axis returns to its
origin.
P39
Return-to-origin speed
(mm/min)
100 to 60000
15000
X, Y axes speed during resetting to the
origin
P756-
P761
Output I/O setting before
resetting
OUT1 to OUT6
/ Not set
Not set
Setting of IO before resetting
P762-
P797
High level / Low
level
High level
P649
Alarm in the case of a
resetting error
Yes/No
No
P782-
P787
Output IO setting after
resetting
OUT1 to OUT6
/ Not set
Not set
Setting of IO after returning to the origin
P788-
P793
High level / Low
level
Low level
Tempo-
rary stop
setting
P40
Automatic thread trimming
during the temporary stop
Yes/No
No
"Yes" : Thread is automatically trimmed
"No" : Thread is not trimmed
P41
Needle position during the
temporary stop
Upper stop
position
/ Lower
stop position
Upper
stop posi-
tion
P45
Type of the temporary stop
switch
Self lock / Nor-
mal
Self lock
In the case the temporary stop switch
type is "Self lock", the temporary stop
function does not automatically oper-
ate when the switch is pressed.
In the case the temporary stop switch
type is "Normal", the temporary stop
function automatically operates when
the switch is pressed.
P799
The presser foot does not
go up during the temporary
stop
Yes/No
No
Statistics
settings
P49
Bobbin thread remaining
amount is cleared at the
time of turning the power
ON
Yes/No
No
Whether the remaining amount of
bobbin thread is reset to 0 (zero) when
turning the power ON
P50
Operation stops after the
bobbin thread has run out
Yes/No
No
In the case of "Yes", the sewing ma-
chine stops when the consumed bobbin
thread length has reached the "entire
length".
P51
Bobbin thread counter
setting is enabled
Yes/No
No
In the case of "Yes", statistics automat-
ically indicate the consumed bobbin
thread length
P46
Bobbin thread counter is
cleared at the time of turn-
ing the power ON
Yes/No
No
Whether the sewing counter is reset to
0 (zero) when turning the power ON