− 111 −
Error code
Description of error
How to recover
E811
Overvoltage of power error
When input power is more than the specified value
Turn OFF the
power.
E813
Low voltage of power error
When input power is less than the specified value
Turn OFF the
power.
E901
Main shaft motor IPM abnormality
When SERVO CONTTROL circuit board is abnormal
Turn OFF the
power.
E903
Stepping motor power (50V) abnormality
When stepping motor power of SERVO CONTROL circuit board
fluctuates more than ± 15%
Turn OFF the
power.
E904
Solenoid power (33V) abnormality
When solenoid power of SERVO CONTROL circuit board fluctu
-
ates more than ± 15%
Turn OFF the
power.
E905
Heat sink temperature for SERVO CONTROL circuit board
abnormality
Turn ON the power again after taking time.
Turn OFF the
power.
E915
Communication abnormality between operation panel and
MAIN CPU
When abnormality occurs in data communication
Turn OFF the
power.
E916
Communication abnormality between MAIN CPU and main
shaft CPU
When abnormality occurs in data communication
Turn OFF the
power.
E917
Communication abnormality between operation panel and
personal computer
When abnormality occurs in data communication
Possible to re-
start after reset.
E918
MAIN circuit board heat sink temperature abnormality
Turn ON the power again after taking time.
Turn OFF the
power.
E943
Defective EEP-ROM of MAIN CPU
When data writing to EEP-ROM cannot be performed
Turn OFF the
power.
Summary of Contents for APW-895NE
Page 2: ......
Page 3: ...APW 895NE IP 420 CompactFlash TM is the registered trademark of SanDisk Corporation U S A ...
Page 4: ......
Page 12: ...viii ...
Page 13: ...ix ...
Page 130: ......
Page 131: ...APW 895NE IP 420 CompactFlash TM 是美国 SanDisk 公司的注册商标 ...
Page 147: ... 7 6 线架的组装和往主机的安装 请按照左图所示那样 请用螺母和垫片把线架固定 到主机机架 上 垫片 弹簧座 螺母 ...
Page 168: ... 28 F 此时 错误画面被显示出来 通知停止开关被按 按了复位按 钮 F 之后 错误被解除 然后返回到输入画面 ...
Page 254: ......
Page 255: ......