![JUKI APW-895NE Instruction Manual Download Page 70](http://html.mh-extra.com/html/juki/apw-895ne/apw-895ne_instruction-manual_2029641070.webp)
− 54 −
No.
Item
Setting range
/
Edit unit
Initial value
Pitch of two stitches before the last stitch of condensation
Pitch of two stitches before the last stitch of condensation sewing at sewing end is set.
*
It is possible to set only when
is set to selection of condensation.
*
It is possible to set only when
is set to selection of condensation/
back tack detailed setting.
0.1 to 1.5
/
0.1mm
1.0mm
※
Number of back tack stitches at sewing end
Number of back tack stitches at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
1 to 12
/
1 stitch
3 stitches
※
Back tack pitch at sewing end
Back tack sewing pitch at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
0.5 to 3.0
/
0.1mm
2.0mm
※
First stitch pitch of return of back tack at sewing end
First stitch pitch of return section of back tack sewing at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
* It is possible to set only when
is set to selection of condensation/
back tack detailed setting.
0.1 to 3.0
/
0.1mm
2.0mm
※
Second stitch pitch of return of back tack sewing at sewing end
Second stitch pitch of return section of back tack sewing at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
* It is possible to set only when
is set to selection of condensation/
back tack detailed setting.
0.1 to 3.0
/
0.1mm
2.0mm
※
Third stitch pitch of return of back tack sewing at sewing end
Third stitch pitch of return section of back tack sewing at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
* It is possible to set only when
is set to selection of condensation/
back tack detailed setting.
0.1 to 3.0
/
0.1mm
2.0mm
※
The last stitch pitch of back tack at sewing end
The last stitch pitch of back tack at sewing end is set.
* It is possible to set only when
is set to selection of back tack.
–2.0 to 2.0
/
0.1mm
–1.5mm
※
※
. . . Item that is not displayed due to other setting state
Summary of Contents for APW-895NE
Page 2: ......
Page 3: ...APW 895NE IP 420 CompactFlash TM is the registered trademark of SanDisk Corporation U S A ...
Page 4: ......
Page 12: ...viii ...
Page 13: ...ix ...
Page 130: ......
Page 131: ...APW 895NE IP 420 CompactFlash TM 是美国 SanDisk 公司的注册商标 ...
Page 147: ... 7 6 线架的组装和往主机的安装 请按照左图所示那样 请用螺母和垫片把线架固定 到主机机架 上 垫片 弹簧座 螺母 ...
Page 168: ... 28 F 此时 错误画面被显示出来 通知停止开关被按 按了复位按 钮 F 之后 错误被解除 然后返回到输入画面 ...
Page 254: ......
Page 255: ......