− 38 −
(3) Counter value changing procedure during sewing
①
Display the counter value change screen
When you desire to change the counter value during the sewing
work, press COUNTER VALUE CHANGE button
A
on the
sewing screen. Counter value change screen is displayed.
②
Change the counter value
Change the counter value with TEN keys
to
B
or ▼▲
button
C
(
D
).
③
Determine the counter value
Press ENTER button
E
and the data is determined. When
you desire to clear the counter value, press CLEAR button
F
.
During the sewing work, the count-up condition is reached the count-
up screen is displayed and the buzzer sounds. Press CLEAR button
A
to reset the counter, and the screen returns to the sewing
screen. And, counting starts again.
(2) Releasing procedure of count-up
A
E
F
D
B
A
C