Installation and operating instructions: JUDO JRSF automatic backwashing protection filter JRSF-ATP DN 125 - 200 (time and differential pressure controlled)
All rights reserved.
JUDO Wasseraufbereitung GmbH
© JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Translation into foreign languages and reproduction, even in excerpt form, is only permitted with special
approval.
Tel. +49 (0)7195-692-0
Fax +49 (0)7195-692-188
Revision level: 24.05.2017
E-mail: [email protected]
judo.eu
53
7.4.1
Spare parts
Model JRSF-ATP
DN125
DN150
DN200
Item
Designation
Pcs
Order no. Order no. Order no.
2 - 4 Replacement part set filter */**
1
2300099
2300101
2300103
4, 15-21 Replacement part complete DN125
1
2635128
–
–
Replacement part complete DN150
1
–
2636128
–
Replacement part complete DN200
1
–
–
2637128
6 O-ring 60x5
1
1635107
1635107
1635107
16 Rubber semi-ellipse
1
2635126
2635126
2635126
22 O-ring 20x2
1
1635115
1635115
1635115
23 Permatight seal
1
1635117
1635117
1635117
34 Linear drive
1
1510165
1510165
1510165
43 Control unit JSK V
1
1510162
1510162
1510162
44 Shut-off valve DN50 EW
1
1980499
–
–
Shut-off valve DN65 EW
1
–
1980500
–
Shut-off valve DN80 EW
1
–
–
1980501
56
JEM 3/2 way solenoid valve G ¼“
1
1510022
1510022
1510022
57
Exhaust throttle G ¼“
1
1980502
1980502
1980502
59 Hose 6x4 mm
1
1100018
1100018
1100018
60.1 Differential pressure gauge 0 - 2.5 bar
1
1610011
1610011
1610011
**** Main switch
1
1500509
1500509
1500509
**** Circuit board with transformer
1
1510173
1510173
1510173
**** Primary fuse (F1)
1
1510149
1510149
1510149
**** Secondary fuse (F2)
1
1500382
1500382
1500382
Tab. 14: Spare parts (item numbers related to Table 13 Parts List)
*
Wear part
**
Custom mesh size available upon request
***
When ordering, please specify the length required in metres
****
Not shown
If a new control unit is required as a spare part, the rated diameter of the relevant JUDO
JRSF automatic backwashing protection filter must be specified with the control unit
order so that the new control unit can be loaded with the filter-specified software in the
factory.
7.5
Transfer confirmation and maintenance log
The attached transfer confirmation must be carefully filled out upon commissioning!
The attached maintenance log must be carefully filled out during maintenance work and
serves as a template for the creation and orderly keeping of an on-going maintenance
book!