Code

 Cable insulation - wire insulation / shield / outer insulation / braiding

Ambient temperature of cable 

2)

I1010

 Silicone / - / silicone / -

-50 to +200 °C

- only for TC (not for "N")

I2010

 FEP / - / silicone / -

-50 to +200 °C

- only for RTD and TC 1x"N" acc. cl. 2

I2C10

 FEP / copper wire braiding / silicone / -

-50 to +200 °C

- only for RTD

I2C20

 FEP / copper wire braiding / FEP / -

-50 to +200 °C

- only for RTD

I204N

 FEP / - / glass fibres / - / stainless steel wire braiding

-50 to +200 °C

- only for RTD 2- and 4-wire

I3030

 PFA / - / PFA / -

-200 to +260 °C

- only for TC

I3C30

 PFA / copper wire braiding / PFA / -

-200 to +260 °C

- only for RTD 2- and 4-wire and TC"K"

I404Z

 Glass fibres / - / glass fibres / galvanized steel wire braiding

-20 to +350 °C

- only for TC (not for "N")

I808N

 Ceramic fibres / - / ceramic fibres / stainless steel wire braiding 

-20 to +800 °C

- only for TC 1x"K"

I9999

 Other

Code

 Wire termination

00

 Flying leads (standard)

01

 Insulated pressing tube according to DIN 46228

02

 Flat connector standard (plug) for single sensor, up to 220 °C 

- only for TC

03

 Flat connector standard (plug) for double sensor, up to 220 °C 

- only for TC

04

 Flat connector mini (plug) for single sensor, up to 220 °C 

- only for TC

22

 Flat connector standard (plug) for single sensor, ceramic up to 650 °C 

- only for TC 1x"K"

24

 Flat connector mini (plug) for single sensor, ceramic up to 650 °C 

- only for TC 1x"K"

09

 Other

 OPTIONAL ACCESSORIES

Code

 Versions for explosive atmosphere of gasses or dusts

 Intrinsically safe version “Ex i“

 (Ex) II 1/2G Ex ia IIC T6...Tx°C Ga/Gb
 (Ex) II 1/2D Ex ia IIIC T85°C...Tx°C Da/Db

Code

 Calibration in customer defined points, including certificate of calibration

KTE31A

 Resistance temperature sensor calibration in three points in range -40 to +600 °C

KTE41A

 Resistance temperature sensor calibration in four points in range -40 to +600 °C

KTE51A

 Resistance temperature sensor calibration in five points in range -40 to +600 °C

KTE32AA

 Thermocouple temperature sensor calibration in three points in range -40 to +660 °C

KTE42AA

 Thermocouple temperature sensor calibration in four points in range -40 to +660 °C

KTE52AA

 Thermocouple temperature sensor calibration in five points in range -40 to +660 °C

KTE32AB

 Thermocouple temperature sensor calibration in three points in range -40 to +1100 °C

KTE42AB

 Thermocouple temperature sensor calibration in four points in range -40 to +1100 °C

KTE52AB

 Thermocouple temperature sensor calibration in five points in range -40 to +1100 °C

KTE9

 Other

Code

 Connectors, fuses of connectors and cables

- only for TC

Z2

 Counterpart of connector (plug), standard version, for single sensor, up to 180 °C 

6)

Z3

 Counterpart of connector (plug), standard version, for double sensor, up to 180 °C 

Z4

 Counterpart of connector (plug), mini version, for single sensor, up to 180 °C 

Z32

 Counterpart of connector (plug), standard version, for single sensor, ceramic up to 650 °C 

Z34

 Counterpart of connector (plug), mini version, for single sensor, ceramic up to 650 °C 

PZ2

 Counterpart of connector (rectangular panel plug), standard version, for single sensor, up to 180 °C  

PZ4

 Counterpart of connector (rectangular panel plug), mini version, for single sensor, up to 180 °C 

PS

 Lock of connection connectors standard, for single sensor

PM

 Lock of connection connectors mini, for single sensor

PK1

 Lock anti pull-up cable, for standard connectors for single sensor

PK2

 Lock anti pull-up cable, for standard connectors for double sensor

PK3

 Lock anti pull-up cable, for mini connectors for single sensor

Code

 Fixing shift pipe unions, holders and distance sleeve

  UPS3M12

 

7)

 Fixing shift pipe union for diameter 3 mm, connecting thread M12x1.5 (see data sheet No. 0126)

   UPS4,5M12

 

7)

 Fixing shift pipe union for diameter 4.5 mm, connecting thread M12x1.5 (see data sheet No. 0126)

 UPS6M20

 

7)

 Fixing shift pipe union for diameter 6 mm, connecting thread M20x1.5 (see data sheet No. 0126)

D3

 Thermometer holder for wallmounting, material stainless steel (for head MA)

PV1

 Distance sleeve diameter 8 mm, length 60 mm (only for code S71 - stem diameter 6 mm) 

Code

 Transmitters for mounting on flange

  P5310 H10

 Transmitter with LHP protocol (see data sheet No. 0824)

  P5310EN2 H10  Transmitter with LHP protocol, (Ex) II 3G Ex nA IIC T4 Gc (see data sheet No. 0824)

  P5311 H10

 Transmitter with LHP protocol with galvanic isolation (see data sheet No. 0824)

  P5311EN2 H10  Transmitter with LHP protocol with galvanic isolation, (Ex) II 3G Ex nA IIC T4 Gc (see data sheet No. 0824)

 P5311EI1 H10  Transmitter with LHP protocol with galvanic isolation, (Ex) II 1G Ex ia IIC T4-T6 Ga,  (Ex) II 1D Ex ia IIIC T106°C Da

 (see data sheet No. 0824)

P5315 H10

 Precision transmitter with LHP protocol with galvanic isolation (see data sheet No. 2098)

P5315EN2 H10  Precision transmitter with LHP protocol with galvanic isolation, (Ex) II 3G Ex nA [ic] IIC T4 Gc (see data sheet No. 2098)

   P5320 H10

 Precision transmitter with HART protocol with galvanic isolation (see data sheet No. 0825)

   P5320EN2 H10  Precision transmitter with HART protocol with galvanic isolation, (Ex) II 3G Ex nA [ic] IIC T4 Gc (see data sheet No. 0825)

   P5320EI1 H10  Precision transmitter with HART protocol with galvanic isolation, (Ex) II 1G Ex ia IIC T4-T6 Ga, (Ex) II 1D Ex ia IIIC Txx°C Da 

 (see data sheet No. 0825)

Code

 Transmitters for mounting for rail

  P5310 L10

 Transmitter with LHP protocol (see data sheet No. 0824)

  P5310EN2 L10  Transmitter with LHP protocol, (Ex) II 3G Ex nA IIC T4 Gc (see data sheet No. 0824)

  P5311 L10

 Transmitter with LHP protocol with galvanic isolation (see data sheet No. 0824)

  P5311EN2 L10  Transmitter with LHP protocol with galvanic isolation, (Ex) II 3G Ex nA IIC T4 Gc (see data sheet No. 0824)

P5315 L10

 Precision transmitter with LHP protocol with galvanic isolation (see data sheet No. 2098)

P5315EN2 L10  Precision transmitter with LHP protocol with galvanic isolation, (Ex) II 3G Ex nA [ic] IIC T4 Gc (see data sheet No. 2098)

 P5320 L10

 Precision transmitter with HART protocol with galvanic isolation (see data sheet No. 0825)

 P5320EN2 L10  Precision transmitter with LHP protocol with galvanic isolation, (Ex) II 3G Ex nA [ic] IIC T4 Gc (see data sheet No. 0825)

 P5320EI3 L10

 Precision transmitter with HART protocol with galvanic isolation, (Ex) II 1G Ex ia IIC T4-T6 Ga, (Ex) II 1D Ex ia IIIC Txx°C Da 
 (see data sheet No. 0825)

        Example of order:    T1560 22 T7 S51 L100 KV 1000 I1 02 Z2 KTE32AB (-40, 500, 1000 °C) PS P1 

• ... Ex stock version               ° ... Marked version can be dispatched up to 5 working days (with calibration up to two weeks)

6)

 … Plug connector is possible to connect to standard or mini male connector.

7)

 … It is suitable only for non-flowing gas medium, free of mechanical stress including impacts and vibrations, where adjustable nominal length is required

        and is impossible to use fixing pipe unions PT because of high temperature.

EI

°

°

°

°

°

°

°

°

°

°

°

°

°
°

°

°

°

°

°

°

°

°

°

°



°

°

°

°
°

°

°

°

°

°

°

°



Summary of Contents for FlexiTEMP 60

Page 1: ...600 Nicrobell Pyrosil Sheath diameter from 1 to 6 mm Optional nominal length L 0 1 to 50 m Fast response to temperature changes Flexible stem Optional version of cold junction with flying leads conne...

Page 2: ...ct description 4 3 1 Application 4 3 2 Description 4 3 3 Dimensional drawings 5 4 Installation operation and maintenance 6 4 1 Installation and commissioning 6 4 2 Operation and maintenance 8 5 Produc...

Page 3: ...s Sensors with fiberglass insulation of wires must be stored in a dry environment 1 6 Installation and commissioning During installation commissioning operation and maintenance follow the instructions...

Page 4: ...with the sheath made of stainless steel 1 4404 for resistance sensors 1 4541 for thermocouple J or Inconel 600 2 4816 Nicrobell Pyrosil for thermocouple K and N Resistance sensors are supplied with si...

Page 5: ...zalit mi v vody dle NAMUR S2 S3 S4 p evodn k H1 hlavice p ipojovac rouben 42 M4 33 L D 42 M4 33 L D L 50 33 D L 62 33 D G1 2 G3 8 44 33 30 8 M4 Parametry proveden krytu dle po adavku instalovan ho p...

Page 6: ...nce has not been lowered 4 1 3 Special conditions for safe use of sensors in Intrinsically safe version code EI 1 Temperature sensors in intrinsically safe version code EI can be connected to intrinsi...

Page 7: ...Max temperature of measured medium T1 450 C 440 C T2 300 C 290 C T3 200 C 195 C T4 135 C 130 C T5 100 C 95 C T6 85 C 80 C For process temperature measured medium 440 C Tm 1200 C the maximal surface te...

Page 8: ...cal parameters it is necessary to replace the sensor 5 Product specifications 5 1 Technical specifications Resistance sensors type T1060 Measuring resistor RTD 1xPt100 accuracy class A B according to...

Page 9: ...rmocouple wires Steel sheath Hot junction Ceramic insulation Thermocouple wires Steel sheath Ceramic insulation Hot junction Steel sheath Thermocouple wires Ceramic insulation Hot junction Flat connec...

Page 10: ...nsmitter 44 mm span of fixing screws M4 33 mm Applicable transmitters For range of transmitter see category optional accessories in transmitters for head mounting and the catalogue transmitters For ap...

Page 11: ...00 C 520 C 1020 C 1100 C S61 4 5 only for TC 620 C 1100 C S71 6 600 C 720 C 1100 C 1200 C S99 Other Code Nominal length of stem L mm L Fill length in mm min length 100 mm Code Cold end version of stem...

Page 12: ...or PK1 Lock anti pull up cable for standard connectors for single sensor PK2 Lock anti pull up cable for standard connectors for double sensor PK3 Lock anti pull up cable for mini connectors for singl...

Page 13: ...meter sheath 3 to 6 mm M04 M20x1 5 only for sensors with diameter sheath 3 to 6 mm M05 M12 only for sensors with diameter sheath 3 to 6 mm only for shift pipe union PB G01 G1 8 only for sensors with d...

Page 14: ...14 Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP 60 8 Appendix 8 1 Declaration of conformity explosion hazard environment version codes EI...

Page 15: ...JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Reviews: