background image

- 10 -

Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP

®

 60

5.4 Supplementary parameters

EMC (electromagnetic compatibility):

Sensors  without  transmitter  do  not  contain  any  source  of 
electromagnetic  interference  and  they  are  not  affected  by 
electromagnetic  fields.  Sensors  with  transmitter  meet  the 
requirements of EN 61326-1.

Lifetime

Lifetime  of  the  product  cannot  be  exactly  determined,  it 
depends on the operational conditions. It is necessary to take 
into account that lifetime (reliability) of the temperature sensors 
may  be  significantly  reduced  e.g.  by  chemical  corrosiveness 
or  abrasion  or  erosion  effects  of  the  measured  medium, 
effects of vibrations or shocks and surges (caused by flowing 
of the medium or transferred to the sensor from the external 
environment,  such  as  from  big  rotary  machines,  etc.),  cyclic 
temperature  changes,  fast  temperature  changes,  use  of  the 
sensors at the upper limit of the temperature range, etc.

5.4.1 Version with transmitter

Sensors FlexiTEMP

®

 60 with codes VV, KS, KM, KV, H1 and 

H1...  are designed for connection with transmitters for a DIN 
rail.  Exchangeable  measuring  insert  (standard  for  sensors 
ModuTEMP

®

  70)  of  versions  with  codes  S2,  S3,  S4  can  be 

completed with transmitters into head. This version is possible 
to apply for all sensor head types of ModuTEMP

®

 70 with outer 

diameter of transmitter 44 mm (span of fixing screws M4 - 33 
mm).

Applicable transmitters

For range of transmitter see category optional accessories in 
transmitters for head mounting and the catalogue transmitters. 
For application in explosion hazard environment, transmitters 
with individual approval have to be selected.

For application with headmounted transmitter, observe 
also the requirements according to transmitter manual.

6. Tests, certificates, standards and marking

6.1 Tests and certificates

Temperature  sensors  FlexiTEMP

®

  60  have  the  following 

certificates and approvals: 
For explosion hazard environment of gasses and dusts:
EC Certificate on type examination, No. FTZÚ 13 ATEX 0079X 
dated  25.6.2013  and  Appendix  No.  1  to  the  certificate  dated 
25.6.2018.
Certified are these types of resistance and thermocouple
temperature sensors: T10...EI and T15...EI.

6.2 Standards and directives

RoHS: 
2011/65/EU
Electromagnetic compatibility: 
EN 61326-1
Sensors into explosion hazard environment: 
EN 60079-0
EN 60079-11

6.3 Marking and type tag information

Marking on temperature sensors head:

Standard version (example):

T1060   

type number

1xPt100/B/4 

number of sensors, sensor material,  

 

 

accuracy class, sensor connection

-200 ..600 °C  

temperature range

3214567  

serial number

JSP, s.r.o. 

address of manufacturer

Raisova 547
506 01 Jičín
Czech Republic

 

 

logo of JSP, s.r.o.

www.jsp.cz  

website address

CE 

  

marking of conformity

Tag of sensor in version EI includes this information:
FTZÚ 13ATEX0079X          

 II 1/2G Ex ia IIC T6...Tx°C Ga/Gb
 II 1/2D Ex ia IIIC T85°C...Tx°C Da/Db

year of manufacture

Summary of Contents for FlexiTEMP 60

Page 1: ...600 Nicrobell Pyrosil Sheath diameter from 1 to 6 mm Optional nominal length L 0 1 to 50 m Fast response to temperature changes Flexible stem Optional version of cold junction with flying leads conne...

Page 2: ...ct description 4 3 1 Application 4 3 2 Description 4 3 3 Dimensional drawings 5 4 Installation operation and maintenance 6 4 1 Installation and commissioning 6 4 2 Operation and maintenance 8 5 Produc...

Page 3: ...s Sensors with fiberglass insulation of wires must be stored in a dry environment 1 6 Installation and commissioning During installation commissioning operation and maintenance follow the instructions...

Page 4: ...with the sheath made of stainless steel 1 4404 for resistance sensors 1 4541 for thermocouple J or Inconel 600 2 4816 Nicrobell Pyrosil for thermocouple K and N Resistance sensors are supplied with si...

Page 5: ...zalit mi v vody dle NAMUR S2 S3 S4 p evodn k H1 hlavice p ipojovac rouben 42 M4 33 L D 42 M4 33 L D L 50 33 D L 62 33 D G1 2 G3 8 44 33 30 8 M4 Parametry proveden krytu dle po adavku instalovan ho p...

Page 6: ...nce has not been lowered 4 1 3 Special conditions for safe use of sensors in Intrinsically safe version code EI 1 Temperature sensors in intrinsically safe version code EI can be connected to intrinsi...

Page 7: ...Max temperature of measured medium T1 450 C 440 C T2 300 C 290 C T3 200 C 195 C T4 135 C 130 C T5 100 C 95 C T6 85 C 80 C For process temperature measured medium 440 C Tm 1200 C the maximal surface te...

Page 8: ...cal parameters it is necessary to replace the sensor 5 Product specifications 5 1 Technical specifications Resistance sensors type T1060 Measuring resistor RTD 1xPt100 accuracy class A B according to...

Page 9: ...rmocouple wires Steel sheath Hot junction Ceramic insulation Thermocouple wires Steel sheath Ceramic insulation Hot junction Steel sheath Thermocouple wires Ceramic insulation Hot junction Flat connec...

Page 10: ...nsmitter 44 mm span of fixing screws M4 33 mm Applicable transmitters For range of transmitter see category optional accessories in transmitters for head mounting and the catalogue transmitters For ap...

Page 11: ...00 C 520 C 1020 C 1100 C S61 4 5 only for TC 620 C 1100 C S71 6 600 C 720 C 1100 C 1200 C S99 Other Code Nominal length of stem L mm L Fill length in mm min length 100 mm Code Cold end version of stem...

Page 12: ...or PK1 Lock anti pull up cable for standard connectors for single sensor PK2 Lock anti pull up cable for standard connectors for double sensor PK3 Lock anti pull up cable for mini connectors for singl...

Page 13: ...meter sheath 3 to 6 mm M04 M20x1 5 only for sensors with diameter sheath 3 to 6 mm M05 M12 only for sensors with diameter sheath 3 to 6 mm only for shift pipe union PB G01 G1 8 only for sensors with d...

Page 14: ...14 Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP 60 8 Appendix 8 1 Declaration of conformity explosion hazard environment version codes EI...

Page 15: ...JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Reviews: