1. General instructions and information

1.1 Symbols used

   

Symbol  of  warning;  for  safe  use  it  is  necessary 

 

to proceed according to the instructions.

   

Symbol  CE  certifies  compliance  of  the  product  with  

 

the respective government directives.

   

This product does not belong to public waste and it is  

 

subjected to separate collection.

   

The product meets requirements for explosion hazard  

 

environment.

   RTD 

Resistance sensor

    TC 

Thermocouple

1.2 Safety warnings and cautions

The  equipment  may  be  installed  only  by  a  qualified 
personnel who are familiar with national and international 
laws,  directives,  standards  and  with  this  instruction 

manual. The equipment shall be supplied from a safe voltage 
source that meets all requirements of the standard EN 61010-1 
and must be-installed in compliance with national requirements 
and standards providing safety.
The instrument may not be used for other purposes than as 
specified in this instruction manual. When the sensor is used  
with  transmitter,  observe  also  the  requirements  according 
to transmitter manual. For elimination of a risk of injury from 
electric shock or fire, the maximum operational parameters of 
the instrument may not be exceeded.

1.3 Scope of delivery

With the product is delivered:

 

- Manual for installation, operation and maintenance

 

- Certificate of calibration (only with calibrated sensors)

 

- Copy  of  EC  certificate  on  type  examination  ATEX  (only 

sensors for explosion hazard environment)

1.4 Description of the delivery and packing

The  product  is  packaged  in  a  protective  cover  and  provided 
with  an  identification  label  with  a  mark  of  the  output  control. 
The product must not be exposed to direct rain, vibrations and 
shocks during transport.

1.5 Storage

The  products  shall  be  stored  at  temperatures  from  +5  °C  to 
+35 °C and maximum relative humidity 80 % in the rooms with 
elimination of condensation of water vapours on the products. 
The  stored  products  shall  not  be  exposed  to  any  shocks, 
vibrations and effects of harmful vapours and gases.
Sensors with fiberglass insulation of wires must be stored in 
a dry environment.

1.6 Installation and commissioning

During installation, commissioning, operation and maintenance 
follow the instructions in chapter 4.

1.7 Spare parts

Any of the compact parts of the product can be also ordered 
as  a  spare  part  if  there  is  not  required  special  procedures 
or  technological operations for the exchange. 

1.8 Repairs

Products  are  repaired  by  the  manufacturer. The  products  for 
repair  should  be  sent  in  a  packing  that  guarantees  damping 
of shocks and vibrations and protects against damage during 
transport.

1.9 Warranty

Products are covered by a warranty for a period of 24 months 
from the delivery date on the delivery note. The manufacturer 
guarantees  technical  and  operational  parameters  of  the 
products  within  scope  of  the  applicable  documentation. 
Warranty period is specified with individual items and begins 
from  the  day  of  takeover  of  the  goods  by  the  purchaser  or 
delivery to the carrier. Any claims concerning to defects of the 
goods  together  can  be  filed  in  writing  with  the  manufacturer 
within  the  warranty  period  and  the  claimed  product  shall  be 
presented. The  claiming  party  shall  give  identification  of  the 
product,  number  of  the  delivery  note  and  description  of  the 
fault or defect. 
The  manufacturer  is  not  responsible  for  any  defects  caused 
by  improper  storage,  incorrect  connection,  damages  caused 
by  external  effects,  in  particular  by  effects  of  factors  with 
excessive  values,  unqualified  installation,  improper  operation 
or common wearing.

2. End of service and disposal

2.1 End of service

Before removing and ending of service of the sensor is at 
first necessary to switch possible control loop to manual 
operation,  or  take  other  appropriate  action  to  prevent 

potential harm associated with the end of sensor operation. For 
sensors with head, the head is opened, connecting wires of the 
sensor  are  disconnected  (cut  off)  and  sensor  is  dismounted. 
For sensors with electric power supply is possible to dismount 
the sensor after the power supply is switched off.

2.2 Disposal

The  products  do  not  contain  any  environmentally  ha-
zardous parts. When disposing the packing and destro-
yed or irreparably damaged product proceed according 

to the local regulations.

Summary of Contents for FlexiTEMP 60

Page 1: ...600 Nicrobell Pyrosil Sheath diameter from 1 to 6 mm Optional nominal length L 0 1 to 50 m Fast response to temperature changes Flexible stem Optional version of cold junction with flying leads conne...

Page 2: ...ct description 4 3 1 Application 4 3 2 Description 4 3 3 Dimensional drawings 5 4 Installation operation and maintenance 6 4 1 Installation and commissioning 6 4 2 Operation and maintenance 8 5 Produc...

Page 3: ...s Sensors with fiberglass insulation of wires must be stored in a dry environment 1 6 Installation and commissioning During installation commissioning operation and maintenance follow the instructions...

Page 4: ...with the sheath made of stainless steel 1 4404 for resistance sensors 1 4541 for thermocouple J or Inconel 600 2 4816 Nicrobell Pyrosil for thermocouple K and N Resistance sensors are supplied with si...

Page 5: ...zalit mi v vody dle NAMUR S2 S3 S4 p evodn k H1 hlavice p ipojovac rouben 42 M4 33 L D 42 M4 33 L D L 50 33 D L 62 33 D G1 2 G3 8 44 33 30 8 M4 Parametry proveden krytu dle po adavku instalovan ho p...

Page 6: ...nce has not been lowered 4 1 3 Special conditions for safe use of sensors in Intrinsically safe version code EI 1 Temperature sensors in intrinsically safe version code EI can be connected to intrinsi...

Page 7: ...Max temperature of measured medium T1 450 C 440 C T2 300 C 290 C T3 200 C 195 C T4 135 C 130 C T5 100 C 95 C T6 85 C 80 C For process temperature measured medium 440 C Tm 1200 C the maximal surface te...

Page 8: ...cal parameters it is necessary to replace the sensor 5 Product specifications 5 1 Technical specifications Resistance sensors type T1060 Measuring resistor RTD 1xPt100 accuracy class A B according to...

Page 9: ...rmocouple wires Steel sheath Hot junction Ceramic insulation Thermocouple wires Steel sheath Ceramic insulation Hot junction Steel sheath Thermocouple wires Ceramic insulation Hot junction Flat connec...

Page 10: ...nsmitter 44 mm span of fixing screws M4 33 mm Applicable transmitters For range of transmitter see category optional accessories in transmitters for head mounting and the catalogue transmitters For ap...

Page 11: ...00 C 520 C 1020 C 1100 C S61 4 5 only for TC 620 C 1100 C S71 6 600 C 720 C 1100 C 1200 C S99 Other Code Nominal length of stem L mm L Fill length in mm min length 100 mm Code Cold end version of stem...

Page 12: ...or PK1 Lock anti pull up cable for standard connectors for single sensor PK2 Lock anti pull up cable for standard connectors for double sensor PK3 Lock anti pull up cable for mini connectors for singl...

Page 13: ...meter sheath 3 to 6 mm M04 M20x1 5 only for sensors with diameter sheath 3 to 6 mm M05 M12 only for sensors with diameter sheath 3 to 6 mm only for shift pipe union PB G01 G1 8 only for sensors with d...

Page 14: ...14 Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP 60 8 Appendix 8 1 Declaration of conformity explosion hazard environment version codes EI...

Page 15: ...JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Reviews: