Symptom Cause Action
The power is not supplied.
Alternatively, the equipment
does not start even if the Power
button of the operation unit is
pressed.
The AC or DC power supply is
not connected.
Connect the AC or DC power
supply.
The breaker at the front of the
power supply unit (NBD-913) is
not set to ON.
Set the breaker to ON by
pushing up the lever of the
breaker.
The AC or DC power supply is
not input within the specified
voltage range.
Connect the AC or DC power
supply within the specified
voltage range.
The internal wiring is faulty.
Make a request to the distributor
for repair.
The power supply unit
(NBD-913) is faulty.
Make a request to the distributor
for repair.
The central control unit
(NDC-1590) is faulty.
Make a request to the distributor
for repair.
The operation unit (NCE-5605)
is faulty.
Make a request to the distributor
for repair.
The power is not supplied to the
monitor.
The display unit is not activated. Activate the display unit.
The internal wiring is faulty.
Make a request to the distributor
for repair.
Display unit (NWZ-208/
NWZ-207/NWZ-214) is faulty.
Make a request to the distributor
for repair.
Although the power is supplied
to the monitor, the screen is not
displayed.
The brightness of the monitor is
set to the minimum level.
Adjust the brightness of the
monitor to the appropriate level.
The internal wiring is faulty.
Make a request to the distributor
for repair.
Display unit (NWZ-208/
NWZ-207/NWZ-214) is faulty.
Make a request to the distributor
for repair.
The brightness of the monitor
cannot be adjusted.
The display unit (NWZ-208/
NWZ-207/NWZ-214) is faulty.
Make a request to the distributor
for repair.
The trackball or the option
keyboard cannot be operated.
The internal wiring is faulty.
Make a request to the distributor
for repair.
The display unit
(NCE-5605/NCE5625) is faulty.
Make a request to the distributor
for repair.
The trackball does cannot be
moved smoothly.
The trackball is dirty.
Clean the trackball.
Summary of Contents for JAN-7202
Page 2: ......
Page 19: ...xvii CWA 246 26inch Display Unit Mount Kit Warning Label ...
Page 20: ...xviii CWA 245 19inch Display Unit Mount Kit Warning Label ...
Page 21: ...xix NQE 3141 4A 8A Interswitch Unit Warning Label ...
Page 22: ...xx EQUIPMENT APPEARANCE CWA 245 Display Unit CWA 246 Display Unit ...
Page 24: ...xxii NWZ 207 214 19inch Display NWZ 208 26inch Display NQE 1143 Junction box Option ...
Page 34: ...Contents 8 ...
Page 50: ...Section 1 Overview 1 16 Outline Drawing of 19inch Desktop Frame CWB 1594 ...
Page 56: ...Section 1 Overview 1 22 ...
Page 66: ...Section 2 Name and Function of Each Unit 2 10 ...
Page 118: ...Section 3 Basic Operations 3 52 ...
Page 166: ...Chapter 4 Conning Display 4 48 ...
Page 256: ...Section 9 Maintenance Inspection 9 48 ...
Page 272: ...Section 10 Failures and After Sale Services 10 16 ...
Page 274: ...Section 11 About Disposal 11 2 ...
Page 331: ......