Table A: Sensors that can be selected on CCU
Serial port
Sensor name
Gyro
Heading Sensor(NMEA), Heading Sensor1(NMEA)
*1
, Heading
Sensor2(NMEA)
*1
Heading Sensor(Gyro I/F), Heading Sensor1(Gyro I/F)
*1
, Heading
Sensor2(Gyro I/F)
*1
LOG
Log(NMEA) , Log1(NMEA)*
2
, Log2(NMEA)*
2
Log(Gyro I/F) *
3
Selector
GPS GPS
1
GPS 2*
4
GPS 3*
4
GPS 4*
4
Selector
AIS AIS
*1: Only when there are two Heading Sensors
*2: Only when two logs are available
*3: Only when Heading Sensor(Gyro I/F) is selected for Gyro of CCU
*4: May not be displayed depending on the number of GPS units.
Setting serial ports on SLC/ALC
Set the serial ports on SLC/ALC that is installed as follows.
Setting item
Description of Setting
Setting value
CH1 to CH8
(RS-422)
1. Click on any of the tabs, SLC1(M) to SLC4(M)/SLC1(S) to
SLC4(S)/ALC1 to ALC4.
2. Enable the serial port of the corresponding channel by
selecting the check box.
3. Select a sensor
*1
to be connected to the corresponding
channel on the [Sensor] combo box. When not selecting a
sensor, select [ - ].
Enable: Select.
Disable: Clear.
CH9/CH10
(RS-422/RS485)
1. Click on any of the tabs, SLC1(M) to SLC4(M)/SLC1(S) to
SLC4(S)/ALC1 to ALC4.
2. Enable the serial port of the corresponding channel by
selecting the check box.
3. Select a sensor
*1
to be connected to the corresponding
channel on the [Sensor] combo box. When not selecting a
sensor, select [ - ].
Enable: Select.
Disable: Clear.
*1: The sensors that can be selected on SLC/ALC are indicated below.
However, the sensors that can be actually selected vary depending on the equipment setting.
Heading Sensor 1, Heading Sensor 2, Log 1, Log 2, GPS 1, GPS 2, GPS 3, GPS 4, Ship's Clock, Echo
Sounder(Depth), Echo Sounder 2(Depth), AIS, NAVTEX, Anemometer(Wind), Water Temperature
Meter, Current Meter, Climate Meter, TRI, Autopilot, Rudder, Engine/Propeller, Engine Telegraph,
Thruster, Azimuth Thruster, Generator, Fin Stabilizer, YEOMAN Digitizer, RADAR1(TT RX),
RADAR2(TT RX), Gyro Switch, Alert(to CAM), Alert(from Subsystem), Alert(to BNWAS), DSC,
IAS(MODBUS), IAS(NMEA), NAV/Alert, Plotter, GPS Buoy
Summary of Contents for JAN-7202
Page 2: ......
Page 19: ...xvii CWA 246 26inch Display Unit Mount Kit Warning Label ...
Page 20: ...xviii CWA 245 19inch Display Unit Mount Kit Warning Label ...
Page 21: ...xix NQE 3141 4A 8A Interswitch Unit Warning Label ...
Page 22: ...xx EQUIPMENT APPEARANCE CWA 245 Display Unit CWA 246 Display Unit ...
Page 24: ...xxii NWZ 207 214 19inch Display NWZ 208 26inch Display NQE 1143 Junction box Option ...
Page 34: ...Contents 8 ...
Page 50: ...Section 1 Overview 1 16 Outline Drawing of 19inch Desktop Frame CWB 1594 ...
Page 56: ...Section 1 Overview 1 22 ...
Page 66: ...Section 2 Name and Function of Each Unit 2 10 ...
Page 118: ...Section 3 Basic Operations 3 52 ...
Page 166: ...Chapter 4 Conning Display 4 48 ...
Page 256: ...Section 9 Maintenance Inspection 9 48 ...
Page 272: ...Section 10 Failures and After Sale Services 10 16 ...
Page 274: ...Section 11 About Disposal 11 2 ...
Page 331: ......