Section
12
Specifications
12-14
12.14 Junction Box
GENERAL SPECIFICATION
NQE-1143: Junction Box
Mechanical
Dimension
Width 400 x Depth 86 x Height 261.5 (mm)
Mass
3.8kg
Environment
Operational Temperature
-15
C to +55
C
Operational Humidity
40
C RH 93%
Vibration
Sweep 2Hz to 13.2Hz at ± 1mm, 13.2Hz to 100Hz at 7m/s
2
and for 2h on each resonance, otherwise 2h at 30Hz in all
three axes
EMC
IEC60945-Ed4.0
Ingress Protection Rating
Front : IP20
Power
Power
21.6 to 31.2 VDC
Input Voltage
48W MAX
Power Consumption
3A
2, 15A
1 Mini Blade Fuse
Over Current Protection
Yes
FUNCTIONAL SPECIFICATION
CMH-2370: Serial LAN Interface Circuit
Interface
IEC61162-1
8 input / 8 output
IEC61162-2
2 input / 2 output
IEC61162-450 1
(100Base-TX)
Dry Contact Output (N.C/N.O
selectable)
8 (32V, 0.8A sink MAX)
Dry Contact Input
8 (5V, 50mA source MAX)
Ingress Protection Rating
Front : IP20
FUNCTIONAL SPECIFICATION
CMJ-554: Gyro Interface Circuit
GYRO
STEP
22 to 70 VDC
SYNC
24 to 115VAC, 50/60/400Hz
RATIO 36
/90
/180
/360
OUTPUT
THS (50Hz)
LOG
PULSE
Dry contact: 30V(max), 50mA(max)
Voltage signal: 0-50V (threshold level is 2V)
RATIO
100/200/400/800 [P/NM]
OUTPUT
VBW (1Hz), VLW (0.1Hz)
FUNCTIONAL SPECIFICATION
CMJ-556: Analog Option Circuit
Interface
Isolated Input
4
Input Signal Range
-10 to 10 VDC or 4 to 20 mA
Summary of Contents for JAN-7202
Page 2: ......
Page 19: ...xvii CWA 246 26inch Display Unit Mount Kit Warning Label ...
Page 20: ...xviii CWA 245 19inch Display Unit Mount Kit Warning Label ...
Page 21: ...xix NQE 3141 4A 8A Interswitch Unit Warning Label ...
Page 22: ...xx EQUIPMENT APPEARANCE CWA 245 Display Unit CWA 246 Display Unit ...
Page 24: ...xxii NWZ 207 214 19inch Display NWZ 208 26inch Display NQE 1143 Junction box Option ...
Page 34: ...Contents 8 ...
Page 50: ...Section 1 Overview 1 16 Outline Drawing of 19inch Desktop Frame CWB 1594 ...
Page 56: ...Section 1 Overview 1 22 ...
Page 66: ...Section 2 Name and Function of Each Unit 2 10 ...
Page 118: ...Section 3 Basic Operations 3 52 ...
Page 166: ...Chapter 4 Conning Display 4 48 ...
Page 256: ...Section 9 Maintenance Inspection 9 48 ...
Page 272: ...Section 10 Failures and After Sale Services 10 16 ...
Page 274: ...Section 11 About Disposal 11 2 ...
Page 331: ......