NXU-2 Operations Manual
3-9
JPS Communications, Inc.
STAT - Return this client's current connection status
STOP <1/2> - Set the serial port stop bits
SUBNET <ip address> - Set IP subnet mask for this unit
TRAN - Place this unit's serial port in transparent mode
VER - Print the software version information for this unit
VOCODER <number> - Select the voice compression method (1-5)
WHAT - Print a description of this unit's settings
3.3.3 Setting Unit IP Address
The first thing you should do is to set the IP address of the unit. The NXU-2 comes from the
factory with a default IP address set to 192.168.1.200. Set the address by typing:
MYIP <IP address>
Where <IP address> is the IP address of the unit in dotted quad notation. All configuration
commands are entered by a carriage return. In this example, if your desired IP address is
192.168.1.1 you would type MYIP 192.168.1.1 and press ENTER
3.3.4 Setting Unit Subnet Mask and Gateway Address
Now set your subnet mask using the SUBNET command. If you are using a gateway, set the
gateway address (the address of your router) using the GATEIP command. If on a LAN with no
gateway, leave the gateway address set at the default address 0.0.0.0.
3.3.5 Using DHCP to Assign IP Parameters
If you have a DHCP server on your network, you may configure the NXU-2 to obtain its IP
address, subnet mask, and gateway address via DHCP. Setting the NXU-2 IP address to 0.0.0.0
will cause it to attempt to contact a DHCP server on power-up. NOTE: Using DHCP is not
recommended for NXU-2 Server units since the IP address assigned by the DHCP server is not
generally known and is subject to change. If DHCP is to be used, it should only be used on
client NXU-2 units.
3.3.6 Setting VoIP Port (Optional)
The default port used by the NXU-2 for the transport of audio across the network is 1221.
Under normal circumstances, this should not be changed. The default port may be changed, if
necessary, by using the PORT command. Type PORT <port number> and press ENTER to
select a new default port. The port number must range from 1 to 65535.
3.3.7 Client/Server Selection
Whether the unit will be a client (a unit which can make and break connections) or a server (a
unit which only accepts connections from a client) will need to be decided. This selection is
made with the CONMODE command. CONMODE 0 configures the unit as a client, while
CONMODE 1 configures the unit as a server. For a client unit, you also need to set the IP
Summary of Contents for NXU-2
Page 12: ...NXU 2 Operations Manual 1 6 JPS Communications Inc This Page Left Intentionally Blank ...
Page 16: ...NXU 2 Operations Manual 2 4 JPS Communications Inc Figure 2 1 Outline Dimensions ...
Page 17: ...NXU 2 Operations Manual 2 5 JPS Communications Inc Figure 2 2 Control and Connector Locations ...
Page 22: ......
Page 52: ...NXU 2 Operations Manual 7 2 JPS Communications Inc This Page Left Intentionally Blank ...