NXU-2 Operations Manual
1-4
JPS Communications, Inc.
1.5 Specifications
Table 1-1
Specifications
RX Audio Input
Input impedance
Balanced 47k ohms, transformer coupled.
Input Level
Incoming signals adjustable from –30 to +11 dBm to set 0 dBm nominal input;
+15 dBm clipping.
Frequency Response
10 Hz to 3600 Hz +/- 2dB.
TX Audio Output
Output Impedance
Unbalanced 10 ohms, AC Coupled.
Output Level
Adjustable from –30 to +11 dBm, 0 dBm nominal factory default; +15 dBm
clipping into a 600 ohm load.
Frequency Response
10 Hz to 3350 Hz +/- 2dBm.
Distortion
0.5% or less (excepting Vocoder).
COR & AUX Input
Input impedance
47k ohm pull-up to +5V.
Polarity
COR: Selectable active low or active high; AUX Inputs: Active low.
Threshold
+2.5V nominal.
Protection
Up To + 100 VDC.
PTT and AUX Output
Output Type
Open drain, 47k ohm pull-up to +5V.
Maximum Sink Current
100 mA.
Max Open Circuit Voltage
+60 VDC.
Serial Interface
Interface Type
RS-232, Asynchronous, Full Duplex.
Baud Rates
300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps.
Connector
DB-9 Male, Standard PC/AT DCE Pinout.
Network Interface
Interface Type
10BASE-T Ethernet, 10Mbps; RJ-45 Connector.
Protocols
Audio and status-UDP, RS-232- TCP.
Audio Vocoder
Selectable, 13, 16, 24, 32, or 64 Kbps data rate.
General/Environmental
Programming/Configuration
Web, Telnet, or RS-232 Interface.
Front Panel
Power, Link Active, Channel Active, and Audio Level LEDs.
Rear Panel
Audio/Data, Serial, Network, and Power Connectors.
Audio/Data Connector
DB-15 Female.
Input Power (12 VDC Nom)
+11 to +15 VDC @ 0.5A max. 12VDC (Wall-cube supplied).
Power Connector
Coaxial Jack, 2.5 mm ID, 5 to 5.5 mm OD; Center Pin Positive; Reverse
Polarity Protected.
Size and Weight
1.7” H x 7”W x 9”D (4.3 x 17.8 x 22.9 cm). 4lbs. (1.8kg).
Temperature
Operating: -20 to +60 degrees C. Storage: -40 to +85 degrees C.
Humidity
Up to 95% @ 55 degrees C.
Shock
MIL-STD-810D, Method 516.3, Procedure VI.
Vibration
MIL-STD-810D, Method 514.3, Category 1.
Summary of Contents for NXU-2
Page 12: ...NXU 2 Operations Manual 1 6 JPS Communications Inc This Page Left Intentionally Blank ...
Page 16: ...NXU 2 Operations Manual 2 4 JPS Communications Inc Figure 2 1 Outline Dimensions ...
Page 17: ...NXU 2 Operations Manual 2 5 JPS Communications Inc Figure 2 2 Control and Connector Locations ...
Page 22: ......
Page 52: ...NXU 2 Operations Manual 7 2 JPS Communications Inc This Page Left Intentionally Blank ...