34
08.6
TIPS FOR THE USER
•
The air change fan starts running automatically according to the temperature of the fumes.
•
Only use original spare parts; original spare parts are available through authorised retailers, authorised Assistance Centres, or
directly from JOLLY-MEC.
•
If the glass becomes very dirty (with visible blackening) while operating on pellets, the causes could be:
- low draught by the flue (clean the flue or check its characteristics).
- Insufficient comburent air (add more air with the combustion fan), clean the air intake.
•
When pellets are not used for a long time (spring-summer period), the hopper, the auger and the basket must be completely
emptied using a vacuum cleaner; clean carefully to prevent that pellet residue deposits there and damages components during
the next start up.
•
Only use recommended fuels under penalty of cancellation of the warranty.
•
Generally with a good quality product, every 500-1000 kg of pellet loaded in the hopper, check that there are no deposits of
sawdust on the bottom, and remove any sawdust there (sawdust reduces the auger’s capacity and creates functional problems
for the stove). With low quality or non-certified pellets the frequency with which the bottom of the hopper needs cleaning to
remove sawdust could become more frequent.
•
The pellets must be fed into the hopper using a scoop. Do not empty the sack directly into the hopper.
•
The fireplace must be closed to prevent smoke from escaping.
•
The pellet hatch must be closed while the machine is running.
•
Check for obstructions in the flue and in the external air intake before starting the machine after a prolonged period of disuse.
•
The stove must not be used as an incinerator. Do not use fuels that are not recommended.
•
The stove must not be modified; any unauthorised modification will automatically invalidate the warranty and release the
manufacture from all liability.
•
The stove must not be placed in direct contact with combustible materials; the minimum distance to be observed is 80 cm (see
CHAP 07.1
)
•
Prompt and systematic maintenance is a fundamental component for perfect operating performance and continuous maximum
heat efficiency.
•
Once a year, have the CAT clean the appliance (Technical Assistance Centre , see
CHAP.08.7 - SCHEDULED PREVENTIVE
MAINTENANCE
).
MORE CLEANING = HIGHER PERFORMANCE
- Pellet combustion products must only be used with the combustion chamber door closed. NEVER open it during
operations.
- Never run the fireplace without electrical current and with fuels other than wood pellets.
- DO NOT TOUCH the parts of the fireplace without cladding, excluding the handles and the regulating controls, as they
are subject to high temperatures.
The room where the fireplace is installed must not directly adjoin multi-floored stairwells; there must not be other boilers, stoves or air
extractors in the same room (except for “C” type appliances).
WARNING
-
Call the Fire Brigade if a fire occurs in the flue.
WARNING