APPLIANCE START AND USE
After professionally installing the room ventilation system, the fume exhaust system, the hydraulic system and electrical system according
to the relevant regulations, the CAT can commission the first start up.
After passing the Service Technician’s inspection, the tank can be filled with pellets of the recommended quality, desired temperature and
power set (we recommend setting level 3) and the device turned on with Button 3. The stove will run until the room probe or thermostat
temperature values are reached.
Whilst operating, with the WORK message on the control unit display, the device has a heating output according to one of the 5 levels
of output set. The device remains in operating mode; i.e. at the heat output level, until the set ambient temperature is exceeded by 0.5
°C. At this point it will switch to the ECO mode function. The device will switch back to WORK mode when the ambient temperature
decreases 1.0°C below the SET ambient temperature.
When operating in WORK mode, the fan speed for the hot air exhausted through the grid depends on the output levels; the higher the
output level, the faster the air will be pumped through the front grid.
With STAND-BY, MENU 5 mode enabled, it is possible to switch off the device if the ambient temperature conditions are satisfied within
the values set for the OFF Delta temperature value. The OFF Delta, is the temperature differential between the SET ambient temperature
and the actual ambient temperature. Therefore if, for instance, the SET ambient temperature is 19°C, with an OFF Delta of 2°C and a
switch-off delay of 5’, when the ambient temperature remains above 21°C for at least 5 minutes, the device will switch off. The device
will remain in STD-BY until the ambient temperature reaches 1°C of the SET ambient temperature which correspond to the automatic
start-up value of the stove. In this condition, the stove is not actually off but is waiting to turn back on if the above conditions are satisfied.
Set SET CHRONO – MENU 2 to time operation start and stop. The crono can be quickly started by pressing Button 1 and 2 on the main
display screen. The CHRONO function should be considered as a timer function, while STAND-BY is a temperature function.
In the event of alarms and/or manual pellet load from MENU 7, message CLEAN BASKET is a warning to be sure not to turn on the stove
with excessive pellets in the brazier. To cancel the message, clean the brazier and press and hold down Button 3 for three seconds.
Loading must be performed if the auger is empty, after a NO PELLET alarm, or after maintenance or cleaning of the container. Every
time the manual pellet load mode is enabled, the firebox MUST be emptied to create the correct conditions for the stove start-up phase.
The device can be switched off while operating with manual intervention by the user or by setting a SET CHRONO or can switch off if
an alarm is triggered following a device malfunction.
In the second case follow the indications provided in CHAP. 09 - FAULT DIAGNOSIS AND TROUBLESHOOTING.
The installation technician must attend appliance inspection since system components may require adjustments
not pertinent to the CAT at this time.
Any additional work by the CAT due to the failure to complete the above adjustments during initial inspection are at the
user’s expense.
WARNING
We recommend activating STAND-BY mode when permitted by factory and/or use conditions. Frequent starts
and stops may cause appliance malfunctions, possible no start alarms and waste energy and fuel.
NOTE