in the flow direction to the receptacle. When the oil is drained (check with the dipstick of the engine)
switch off the pump immediately by moving the integrated switch to its centre position. Change the oil
receptacle to the container with new oil. Start the pump by pressing the switch in the flow direction to
the motor. Use the dipstick of the engine to make sure the right amount of oil has been filled into the
engine. Note! As soon as all oil has been drained from the engine, or when the container for refilling oil
into the engine is empty, the pump must be stopped immediately. Otherwise there is a risk of dry running
which will damage the impeller.
Wiring dimensions
(based on 3% voltage drop)
Wire size
Max wire length in m*
F2P10-19
F3B-19
F3B-10 Oil Change
F38B-19
F4B-19
12V
24V
12V
24V
12V
24V
12V
24V
1,5 mm
2
3,7 m
14,6 m
3,7 m
14,6 m
2,5 mm
2
6,1 m
24,4 m
6,1 m
24,4 m
2,7 m
11,0 m
2,7 m
11,0 m
4 mm
2
9,8 m
9,8 m
4,4 m
17,6 m
4,4 m
17,6 m
6 mm
2
14,6 m
14,6 m
6,6 m
26,3 m
6,6 m
26,3 m
10 mm
2
24,4 m
24,4 m
17,6 m
17,6 m
25 mm
2
27,4 m
27,4 m
* The wire length is the total distance from the battery to the pump and back to the battery. It is
recommended to use a relay to shorten the main leaders.
Wiring table
All DC pumps
F3B-19 Oil Change
Electrical installation
F2P10-19
Connect power supply according to picture.
Max 0,2 m
Terminal
fuse
Terminal
fuse
Black
Pump
Pump
Black
Green/yellow
Green/yellow
Red
Red
Switch
Max 0,2 m
IN
IN
+ RED
- RED
11
Original instructions
> English