JOHNSON CONTROLS
22
FORM 150.72-NM1 (1020)
Product Description
ACCESSORIES AND OPTIONS
Power Options
Compressor Power Connections
Single-point terminal block connection(s) are provided
as standard. The following power connections are
available as options.
(See electrical data for specific
voltage and options availability.)
(Factory-mounted)
Single-Point Supply Terminal Block
Includes enclosure, terminal-block and interconnecting
wiring to the compressors. Separate external protection
must be supplied, by others, in the incoming compressor-
power wiring. (Do not include this option if either the
Single-Point Non-Fused Disconnect Switch or Single-
Point Circuit Breaker options have been included.)
Single-Point Non-Fused Disconnect Switch
Or Multiple-Point Non-Fused Disconnect
Swithches
Unit-mounted disconnect switch (es) with external,
lockable handle (in compliance with Article 440-14 of
N.E.C.), can be supplied to isolate the unit power voltage
for servicing. Separate external fusing must be supplied,
by others in the power wiring, which must comply with
the National Electrical Code and/or local codes.
Single-Point Non-Fused Disconnect Switch
With Individual System Breakers
Includes unit-mounted disconnect switch with external,
lockable handles (in compliance with Article 440-14
of N.E.C.) to isolate unit power voltage for servicing.
Factory interconnecting wiring is provided from the
disconnect switch to factory supplied system circuit
breakers.
Single-Point Circuit Breaker
A unit mounted circuit breaker with external, lockable
handle (in compliance with N.E.C. Article 440-14);
can be supplied to isolate the power voltage for
servicing. (This option includes the Single-Point Power
connection.)
Control Transformer
Converts unit power voltage to 115-1-60 (2.0 or 3.0
KVA capacity). Factory mounting includes primary
and secondary wiring between the transformer and the
control panel.
(Factory-mounted)
Power Factor Correction Capacitors
Will correct unit compressor power factors to between
0.90-0.95.
(Factory-mounted)
Control Options
Ambient Kit (Low)
Units will operate to 25.0°F (-3.9°C). This accessory
includes all necessary components to permit chiller
operation to 0°F (-18°C). (This option includes the
Discharge Pressure Transducer / Readout Capability
option.) For proper head pressure control in applications
below 30°F (-1°C) where wind gusts may exceed
5 mph, it is recommended that Optional Condenser
Louvered Enclosure Panels also be included.
(Factory-
mounted)
Ambient Kit (High)
Required if units are to operate when the ambient
temperature is above 115°F (46°C). Includes discharge
pressure transducers.
Language LCD And Keypad Display
Spanish, French, German, and Italian unit LCD controls
and keypad display available. Standard language is
English.
Compressor, Piping, Evaporator Options
Low Temperature Brine
Required for brine chilling below 30°F (-1°C) leaving
brine temperature. Option includes resized thermal
expansion valve.
Chicago Code Relief Valves
Unit will be provided with relief valves to meet Chicago
code requirements.
(Factory-mounted)
Service Isolation Valve
Service suction and discharge (ball type) isolation valves
are added to unit per system. This option also includes
a system high pressure relief valve in compliance with
ASHRAE 15.
(Factory-mounted)
Hot Gas By-Pass
Permits continuous, stable operation at capacities below
the minimum step of compressor unloading to as low as
5% capacity (depending on both the unit and operating
conditions) by introducing an artificial load on the
cooler. Hot gas by-pass is installed on only refrigerant
system #1 on two-circuited units.
(Factory-mounted)
Summary of Contents for YORK Tempo YLAA Series
Page 4: ...JOHNSON CONTROLS 4 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 12: ...JOHNSON CONTROLS 12 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 14: ...JOHNSON CONTROLS 14 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 18: ...JOHNSON CONTROLS 18 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...JOHNSON CONTROLS 36 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 49: ...FORM 150 72 NM1 1020 49 JOHNSON CONTROLS THIS PAGE INTENTIONALLY LEFT BLANK...
Page 71: ...FORM 150 72 NM1 1020 71 JOHNSON CONTROLS THIS PAGE INTENTIONALLY LEFT BLANK...
Page 73: ...FORM 150 72 NM1 1020 73 JOHNSON CONTROLS 5 5...
Page 75: ...FORM 150 72 NM1 1020 75 JOHNSON CONTROLS 5 5...
Page 77: ...FORM 150 72 NM1 1020 77 JOHNSON CONTROLS 5 5...
Page 79: ...FORM 150 72 NM1 1020 79 JOHNSON CONTROLS 5 5...
Page 81: ...FORM 150 72 NM1 1020 81 JOHNSON CONTROLS 5 5...
Page 83: ...FORM 150 72 NM1 1020 83 JOHNSON CONTROLS 5 5...
Page 85: ...FORM 150 72 NM1 1020 85 JOHNSON CONTROLS 5 5 LD13901...
Page 87: ...FORM 150 72 NM1 1020 87 JOHNSON CONTROLS 5 5...
Page 89: ...FORM 150 72 NM1 1020 89 JOHNSON CONTROLS 5 5 LD13232...
Page 91: ...FORM 150 72 NM1 1020 91 JOHNSON CONTROLS THIS PAGE INTENTIONALLY LEFT BLANK...
Page 92: ...JOHNSON CONTROLS 92 FORM 150 72 NM1 1020 Technical Data WIRING LD13238 FIG 22 WIRING...
Page 93: ...FORM 150 72 NM1 1020 93 JOHNSON CONTROLS 5 5 LD13239...
Page 176: ...JOHNSON CONTROLS 176 FORM 150 72 NM1 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 191: ...FORM 150 72 NM1 1020 191 JOHNSON CONTROLS 10 NOTES...