Section 4: Programming Options
Default:
Enabled
Valid range:
1-4
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Disabled
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default:
24-hour Temperature
Valid range:
24-hour Temperature
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 39 for attribute
definitions.
Door Chime
Disabled
Alarm Report
Enabled
Burglary Verified
Disabled
Transmission Delay
Enabled
Bell Audible
Enabled (read-only)
Bell Steady
Enabled (read-only)
Bypass Enable
Enabled (read-only)
Force Arm
Disabled (read-only)
Swinger Shutdown
Disabled (read-only)
Two Way Audio
Disabled (read-only)
Talk Listen
Disabled (read-only)
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
Temperature Format
This section is used to select the scale temperature is dis-
played in.
Default:
F
Valid range:
F (Fahrenheit), C (Celsius)
High Temperature Warning
This option is used to set the temperature threshold for activ-
ating the High Temperature warning indicator. A high tem-
perature warning sounds an audible alert but does not
send a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default:
999
Valid range:
-999 to 999
High Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the High Temperature alarm.
This option is disabled by entering -999 or 999.
Default:
999
Valid range:
-999 to 999
Low Temperature Warning
This option is used to set the temperature threshold for activ-
ating the Low Temperature warning indicator. A low tem-
perature warning sounds an audible alert but does not send
a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default:
999
Valid range:
-999 to 999
Low Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the Low Temperature alarm.
This option is disabled by entering -999 or 999.
Default:
999
Valid range:
-999 to 999
4.6.8 Wireless Flood Configurations
The following sections are used for programming wireless
flood sensors.
Note:
Wireless Flood feature was not evaluated by UL/ULC.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to assign the wireless device to an avail-
able partition.
Default:
1
Valid range:
1-4
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
- 32 -