Section 4: Programming Options
Users assigned to this level are limited to an assigned par-
tition and have reduced system access. These functions
include:
l
Arm/disarm
l
Enable/disable chime
l
View system troubles
Level 0: Professional Installer
Has permission to enable WPS mode (to enable local pro-
gramming access to the panel via the installer app) and also
initiate phone test.
User Name (label)
This option is used to program a system user name.
Default:
Blank
Valid range:
32 character ASCII
User Enable (Locked)
This option is used to control access to the security system
for the selected user. When enabled, the user can access all
functionality available to their user level. When disabled, the
user is locked out of the system.
Default:
Disabled
Valid range:
Enabled/Disabled
4.6.3 Wireless Siren Configuration
Options
The following section provides descriptions of all wireless
siren programming options.
Siren Label
This option is used to program a label for the device.
Default:
Siren 1
Valid range:
32 character ASCI
Siren Enable/Disable
This option is used to enable and disable the wireless siren.
Default:
Enabled
Valid range:
Enabled/Disabled
Siren Partition Assignment
This option is used to assign the wireless siren to an avail-
able partition.
Default:
1
Valid range:
1-4
Fire Alarm
When this option is enabled, the wireless siren sounds dur-
ing fire alarms.
Default:
Enabled
Valid range:
Enabled/Disabled
CO Alarm
When this option is enabled, the wireless siren sounds dur-
ing CO alarms.
Default:
Enabled
Valid range:
Enabled/Disabled
Burg Alarm
When this option is enabled, the wireless siren sounds dur-
ing burglary alarms.
Default:
Enabled
Valid range:
Enabled/Disabled
Flood Alarm
When this option is enabled, the wireless siren sounds for
flood alarms.
Default:
Enabled
Valid range:
Enabled/Disabled
Auto Tamper Alarm
When this option is enabled, the wireless siren sounds dur-
ing tamper alarms.
Default:
Disabled
Valid range:
Enabled/Disabled
Activity LED
When this option is enabled, the Activity LED flashes every
few seconds to indicate that the siren is enrolled and active.
Default:
Disabled
Valid range:
Enabled/Disabled
Volume Control
This option is used to control the volume of the wireless
siren.
Default:
Medium. (Note: UL/ULC installation use Medium setting.)
Valid range:
Low, Medium, High
Squawk Control
This option is used to control wireless siren behavior during
an alarm.
Default:
Sounder Only
Valid range:
Disabled, Sounder Only, Strobe Only, Sounder and Strobe
Exit/Entry Beeps
When this option is enabled, the wireless siren beeps
whenever entry/exit zones are tripped.
Note:
When set to Disable in Stay Mode, the siren still
beeps on entry/exit when the system is armed in Away
mode.
Default:
Disabled
Valid range:
Disabled, Enabled, Disable in Stay Mode