Section 4: Programming Options
Communication Trouble Delay Time
This option is used to program the amount of time before the
following troubles are transmitted to the central monitoring
station:
l
Ethernet trouble
l
Cellular trouble
l
Supervision trouble
l
WIFI trouble
Default:
000
Valid range:
000 to 254 seconds, 000=Instant, 255=Disabled
Visual Verification
This feature enables the central monitoring station operator
to view images captured via installed camera/motion detect-
ors during an alarm.
Visual verification sessions are triggered by the following:
l
Fire key
l
Medical key
l
Panic key
l
Alarms detected by armed PIR cameras
Note:
The microphone on the camera PIR can be disabled.
Default:
Enabled
Valid range:
Enabled/Disabled
Video on Demand
When this option is enabled, the central monitoring station
can request a video image file from an installed cam-
era/motion detector within 60 minutes of an alarm.
Default:
Enabled
Valid range:
Enabled/Disabled
Firmware update Over Cellular
Default: Disabled
Valid range: Enabled, Disabled
Enabled: Installers can perform remote firmware updates via
cellular radio.
Disabled: Firmware updates cannot be performed via cel-
lular radio.
4.4 2-Way Voice Options
Alternate Phone Number
This section is used to program the SIM phone number.
Default:
Blank or Auto-populated
Valid range:
32-Digit Phone Number
Two Way Voice
When this option is enabled, Talk/Listen-in capability for
audio verification of alarms is available.
Default:
Disabled
Valid range:
Enabled/Disabled
Microphone Gain
This section is used to program the volume level of the built-
in microphone. 001 is the lowest volume level. 000 disables
the microphone.
Default:
001
Valid range:
000 to 255
Voice Volume
This option is used to program the volume level of the built-
in speaker. 000 disables the speaker.
Default:
004
Valid range:
000 to 255
4.5 Partition Configuration
Options
This section describes programming options used to con-
figure individual partitions.
Partition Label
This option is used to add a unique label to each partition on
the system. This label is displayed on partition keypads and
event messages.
Default:
Blank
Valid range:
32 character ASCII
Partition Account Number
This option is used to add a unique account number to a par-
tition. When using formats other than SIA, the account num-
ber identifies the alarm system to the central monitoring
station when communicating partition-specific events.
Note:
The iotega will not communicate if the account num-
ber is not programmed.
Default:
FFFF
Valid range:
0001 to FFFF (FFFF to disable communication)
Entry Delay 1
This value determines the entry delay time for Delay 1 type
zones.
Default:
30 seconds.
Max. 45 seconds required for UL/ULC
Valid range:
0 to 255 (standard)
30 to 255 Seconds (UL/ULC)
Entry Delay 2
This value determines the entry delay time for Delay 2 type
zones.
Default:
45 seconds (standard)
Max. 45 seconds required for UL/ULC
Valid range:
0 to 255 (standard)
30 to 255 seconds (UL/ULC)
- 25 -