Section 4: Programming Options
Default:
Disabled
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This programming section is used to program a zone type
for the device.
Default: Instant
Valid
range:
Instant, Interior Follower, Interior Stay/Away, Delay Stay/Away, 24
Hour Supervisory Buzzer, 24 Hour Non Alarm
Device Label
This section is used to program a custom label for the
device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This option is used to customize zone operation. The fol-
lowing attributes are available for the temperature sensor:
Door Chime
Disabled
Alarm Report
Enabled
Burglary Verified
Disabled
Transmission Delay
Enabled
Bell Audible
Enabled (read-only)
Bell Steady
Disabled (read-only)
Bypass Enable
Disabled (read-only)
Force Arm
Disabled (read-only)
Swinger Shutdown
Disabled (read-only)
Two Way Audio
Disabled (read-only)
Talk Listen
Disabled (read-only)
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
4.6.9 Wireless PIR CAM Con-
figurations
The following sections are used to program wireless PIR
Camera motion detectors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to assign the wireless device to an avail-
able partition.
Default:
1
Valid range:
1-4
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Device Label
This section is used to program a custom label for the
device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Type
This programming section is used to program a zone type
for the device.
Default: Instant
Valid
range:
Instant, Interior Follower, Interior Stay/Away, Delay Stay/Away, 24
Hour Supervisory Buzzer, 24 Hour Non Alarm
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 39 for attribute
definitions.
Door Chime
Disabled
Alarm Report
Enabled
Burglary Verified
Enabled
Transmission Delay
Enabled
Bell Audible
Enabled (read-only)
Bell Steady
Enabled (read-only)
Bypass Enable
Enabled (read-only)
Force Arm
Disabled (read-only)
Swinger Shutdown
Enabled (read-only)
Two Way Audio
Enabled (read-only)
Talk Listen
Enabled (read-only)
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
Alarm LED
This option is used to enable/disable the device’s onboard
LED. When enabled, the LED activates when an alarm
- 33 -