Enrolling the module
Before you enroll the module, ensure that all hardwired zones, PGM, AUX, and BELL are wired to the
module.
To enroll the module, complete the following steps:
1. Enable enrollment through panel programming. For more information, refer to the
Qolsys
IQPanel2/IQPanel4 Installation Manual.
2. Press the
Enroll
button on the PCB and release when the LED lights solid orange.
3. Confirm the correct module ID in panel programming.
Note:
The module ID is on the module label. It is a seven digit number that identifies the
device being enrolled. It has the format 460-XXXX.
Testing the module placement
To test the signal strength between the module and the alarm panel, complete the following steps:
•
Press the
Enroll
button on the module.
After the placement test is complete, the color of the LED indicates the signal strength. For more
Table 11: Device signal strength
LED color
Signal strength
Three red flashes
Poor
Three orange flashes
Medium
Three green flashes
Strong
Note:
For UL installations, only a strong signal strength is acceptable.