120
E88
The rotating speed of the main shaft exceeds the safety
limit.
E89
A key is jammed.
•
Find and release the jammed key, call service if
necessary.
E92
Gauge arm for distance and rim diameter is defective.
•
Call service.
•
As long as the gauge arms defective, enter distance
and nominal rim dimensions by pressing the
function keys and rotating the wheel (§ 5.3.3.3).
H0
Wheel running conditions cannot be improved by
optimization.
H1
Further optimization not recommended but feasible.
H2
Weight minimization is recommended, optimization can
achieve no further improvement.
H3
Optimization not recommended.
H20
Correction plane cannot be re-located with the gauge
arm for distance and rim diameter.
•
Measure the correction plane and switch to dynamic
unbalance reading.
H21
The indexed position is not the one for the correction
plane in which the adhesive weight is to be fitted with
the gauge arm.
•
Index the correct position for this correction plane
prior to fitting the adhesive weight.
H80
Readjustment feature not foreseen during basic
calibration.
Consequently readjustment by the operator is not
possible.
•
_ Press on STOP key, error code is deleted.
•
_ Call service for calibration of the machine.
H82
The self-test was disturbed (e.g. by rotating the wheel).
•
The message is displayed for 3 seconds, after which
the measurement is repeated (max. 10 times), or
aborted by pressing the STOP key.