53
5.3.3.5-3
5.3.3.6-1
•
Clean the fitting position before attaching the
adhesive weights.
•
Raise the gauge arm (1, Fig. 5.3.3.5-3) and pull the
holding ring of the gauge head (2, Fig. 5.3.3.5-3)
inwards.
•
Insert the adhesive weight (3, Fig. 5.3.3.5-3) into
the head with the protective foil facing upwards
symmetrically relative to the arrow (4, Fig. 5.3.3.5-
3).
•
Press the adhesive weight firmly against the head
and remove the protective foil from the weight.
•
Pull the gauge arm towards application position AP1.
•
The display shows the position of the gauge arm
for distance and diameter. If the application position
AP1has been reached, a little red arrow becomes
green and an audible signal is given.
•
Swing the gauge arm out towards the rim and press
the weight firmly against the rim using the ejector
(5, Fig. 5.3.3.5-3).
•
Swing the gauge arm in and return it to its home
position.
•
Firmly press the adhesive weight on the rim by hand.
Fit the second adhesive weight for AP2 in the same
manner.
5.3.3.6 Determining the position of the hidden
weight (Alu 3S)
Note
Enter nominal rim width before determining the position
of the weights.
•
After having selected Alu 3 on the screen WEIGHT
PLACEMENT, press menu key F4 to choose
balancing mode Alu 3S.
Alu 3S appears on the screen (Fig. 5.3.3.6-1).
•
Return to the screen RIM DATA INPUT by pressing
the ESC key.
Recommendation
Clamp an adhesive weight in the weight holder of the
gauge
head with the cover film of the weight being in top
position prior
to scanning the correction dimensions.
Fig. 5.3.3.6-2 Scanning of the exact correction
dimensions
a Positioning of the gauge arm for application position
AP1
b Positioning of the gauge arm for application position
AP2
c Exact application position AP1 and AP2